Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 193

The DOI matches its Crossref record.

A Comparison of Magnetoencephalography, MRI, and V‐EEG in Patients Evaluated for Epilepsy Surgery

Wheless, J. W., Willmore, L. J., Breier, J. I., Kataki, M., Smith, J. R., King, D. W., Meador, K. J., Park, Y. D., Loring, D. W., Clifton, G. L., Baumgartner, J., Thomas, A. B., Constantinou, J. E. C., Papanicolaou, A. C. · 1999 · Epilepsia

Abstract

Summary: Purpose: To determine the efficacy and relative contribution of several diagnostic methods [ictal and interictal scalp and intracranial EEG, magnetic resonance imaging (MRI), and magnetoencephalography (MEG)] in identifying the epileptogenic zone for resection. Methods: This was a prospective study using a masked comparison‐to‐criterion standard. Fifty‐eight consecutive patients with refractory partial epilepsy from two university comprehensive epilepsy programs were studied. Patients who were evaluated for and underwent epilepsy surgery were recruited. The main outcome measure was the efficacy of each diagnostic method to identify the resected epileptogenic zone, when referenced to surgical outcome. Results: MEG (52%) was second only to ictal intracranial V‐EEG in predicting the epileptogenic zone for the entire group of patients who had an excellent surgical outcome (seizure free or rare seizure). In a subanalysis, for patients who had temporal lobe surgery, this same relation was seen (MEG, 57%, ictal intracranial V‐EEG, 62%). With extratemporal resection, ictal (81%) and interictal (75%) intracranial EEG were superior to MEG (44%) in predicting the surgery site in those patients with an excellent outcome. Finally, for all patients who had a good surgical outcome, MEG (52%) was better than ictal (33%) or interictal (45%) scalp VEEG in predicting the site of surgery. Conclusions: These results indicate that MEG is a very promising diagnostic method and raise the possibility that it may obviate the need for invasive EEG in some cases or reduce the length of scalp EEG evaluation in others.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1157.1999.tb00800.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Wheless, J. W., Willmore, L. J., Breier, J. I., Kataki, M., Smith, J. R., King, D. W., Meador, K. J., Park, Y. D., Loring, D. W., Clifton, G. L., Baumgartner, J., Thomas, A. B., Constantinou, J. E. C., & Papanicolaou, A. C.
Venue
Epilepsia
Publisher
Wiley
Published
1999-07
Volume
40
Issue
7
Pages
931-941
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2029504578
Cited by
193
References
0
FWCI
7.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Magnetoencephalography, MRI, and V‐EEG in Patients Evaluated for Epilepsy Surgery. https://app.cochat.ai/papers/10.1111/j.1528-1157.1999.tb00800.x
The paper
Wheless, J. W., Willmore, L. J., Breier, J. I., Kataki, M., Smith, J. R., King, D. W., Meador, K. J., Park, Y. D., Loring, D. W., Clifton, G. L., Baumgartner, J., Thomas, A. B., Constantinou, J. E. C., & Papanicolaou, A. C. (1999). A Comparison of Magnetoencephalography, MRI, and V‐EEG in Patients Evaluated for Epilepsy Surgery. Epilepsia. https://doi.org/10.1111/j.1528-1157.1999.tb00800.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.