A Comparison of Magnetoencephalography, MRI, and V‐EEG in Patients Evaluated for Epilepsy Surgery
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: To determine the efficacy and relative contribution of several diagnostic methods [ictal and interictal scalp and intracranial EEG, magnetic resonance imaging (MRI), and magnetoencephalography (MEG)] in identifying the epileptogenic zone for resection. Methods: This was a prospective study using a masked comparison‐to‐criterion standard. Fifty‐eight consecutive patients with refractory partial epilepsy from two university comprehensive epilepsy programs were studied. Patients who were evaluated for and underwent epilepsy surgery were recruited. The main outcome measure was the efficacy of each diagnostic method to identify the resected epileptogenic zone, when referenced to surgical outcome. Results: MEG (52%) was second only to ictal intracranial V‐EEG in predicting the epileptogenic zone for the entire group of patients who had an excellent surgical outcome (seizure free or rare seizure). In a subanalysis, for patients who had temporal lobe surgery, this same relation was seen (MEG, 57%, ictal intracranial V‐EEG, 62%). With extratemporal resection, ictal (81%) and interictal (75%) intracranial EEG were superior to MEG (44%) in predicting the surgery site in those patients with an excellent outcome. Finally, for all patients who had a good surgical outcome, MEG (52%) was better than ictal (33%) or interictal (45%) scalp VEEG in predicting the site of surgery. Conclusions: These results indicate that MEG is a very promising diagnostic method and raise the possibility that it may obviate the need for invasive EEG in some cases or reduce the length of scalp EEG evaluation in others.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Fundamentals if dipole source potential analysis
Scherg, M. (1990) · Max Planck Institute for Plasma Physics · Cited by 530
Tesche, C. D., Uusitalo, M. A., Ilmoniemi, R. J., Huotilainen, M., Kajola, M., & Salonen, O. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00064-6 · Cited by 355
Biomagnetism: Clinical Aspects
Hoke, M. (1992) · Cited by 235
Neuromagnetic Localization of Epileptiform Spike Activity in the Human Brain
Barth, D. S., Sutherling, W., Engel, J., & Beatty, J. (1982) · Science · doi:10.1126/science.6813968 · Cited by 229
Barth, D. S., Sutherling, W., Engle, J., & Beatty, J. (1984) · Science · doi:10.1126/science.6422552 · Cited by 199
Stefan, H., Schneider, S., Feistel, H., Pawlik, G., Schüler, P., Abraham‐Fuchs, K., Schlegel, T., Neubauer, U., & Huk, W. J. (1992) · Epilepsia · doi:10.1111/j.1528-1157.1992.tb02195.x · Cited by 149
Magnetoencephalography and Epilepsy Research
Rose, D. F., Smith, P. D., & Sato, S. (1987) · Science · doi:10.1126/science.3310234 · Cited by 124
The magnetic field of complex partial seizures agrees with intracranial localizations
Sutherling, W. W., Crandall, P. H., Engel, J., Darcey, T. M., Cahan, L. D., & Barth, D. S. (1987) · Annals of Neurology · doi:10.1002/ana.410210605 · Cited by 119
Sutherling, W. W., & Barth, D. S. (1989) · Annals of Neurology · doi:10.1002/ana.410250409 · Cited by 114
Localization of magnetic interictal discharges in temporal lobe epilepsy
Rose, D. F., Sato, S., Smith, P. D., Porter, R. J., Theodore, W. H., Friauf, W. S., Bonner, R. F., & Jabbari, B. (1987) · Annals of Neurology · doi:10.1002/ana.410220311 · Cited by 81
Magnetoencephalographic localization of epileptic cortex—impact on surgical treatment
Paetau, R., Kajola, M., Karhu, J., Nousiainen, U., Partanen, J. V., Tiihonen, J., Vapalahti, M. P., & Hari, R. (1992) · Annals of Neurology · doi:10.1002/ana.410320119 · Cited by 78
Stefan, H., Schüler, P., Abraham‐Fuchs, K., Schneider, S., Gebhardt, M., Neubauer, U., Hummel, C., Huk, W. J., & Thierauf, P. (1994) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1994.tb05192.x · Cited by 75
Biomagnetic measurements of spontaneous brain activity in epileptic patients
Modena, I., Ricci, G., Barbanera, S., Leoni, R., Romani, G. L., & Carelli, P. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90116-x · Cited by 74
Generator sites of spontaneous MEG activity during sleep
Lu, S.-T., Kajola, M., Joutsiniemi, S.-L., Knuutila, J., & Hari, R. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90166-f · Cited by 66
Study of focal epilepsy by multichannel neuromagnetic measurements
Ricci, G., Romani, G. L., Salustri, C., Pizzella, V., Torrioli, G., Buonomo, S., Peresson, M., & Modena, I. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90204-5 · Cited by 54
MAGNETOENCEPHALOGRAPHY AND MAGNETIC SOURCE IMAGING: Capabilities and Limitations
Gallen, C. C., Hirschkoff, E. C., & Buchanan, D. S. (1995) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(25)00292-8 · Cited by 54
Localization of epileptic foci using a large‐area magnetometer and functional brain anatomy
Tiihonen, J., Hari, R., Kajola, M., Nousiainen, U., & Vapalahti, M. P. (1990) · Annals of Neurology · doi:10.1002/ana.410270310 · Cited by 50
Probabilistic reconstruction of multiple sources in the bioelectromagnetic inverse problem
Greenblatt, R. E. (1993) · Inverse Problems · doi:10.1088/0266-5611/9/2/008 · Cited by 48
Magnetoencephalography in the study of epilepsy
Paetau, R., Kajola, M., & Hari, R. (1990) · Neurophysiologie Clinique · doi:10.1016/s0987-7053(05)80153-4 · Cited by 31
Magnetoencephalographic localization of interictal spike sources
Eisenberg, H. M., Papanicolaou, A. C., Baumann, S. B., Rogers, R. L., & Brown, L. M. (1991) · Journal of neurosurgery · doi:10.3171/jns.1991.74.4.0660 · Cited by 29
Self-citationComparison of magnetoencephalography with other functional imaging techniques
Ioannides, A. A. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/a/005 · Cited by 9
Cited by
Thijs, R. D., Surges, R., O'Brien, T. J., & Sander, J. W. (2019) · The Lancet · doi:10.1016/s0140-6736(18)32596-0 · Cited by 2,183
Presurgical evaluation of epilepsy
Rosenow, F. (2001) · Brain · doi:10.1093/brain/124.9.1683 · Cited by 1,669
Magnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases
Stefan, H. (2003) · Brain · doi:10.1093/brain/awg239 · Cited by 304
Conductivities of Three-Layer Live Human Skull
Akhtari, M., Bryant, H. C., Mamelak, A. N., Flynn, E. R., Heller, L., Shih, J. J., Mandelkem, M., Matlachov, A., Ranken, D. M., Best, E. D., et al. (2002) · Brain Topography · doi:10.1023/a:1014590923185 · Cited by 240
“…et al. 1988a; Wood et al. 1988), localization of interictal spike and epileptic activity (Hisada et al. 2000; Michel et al. 1999; Silva et al. 1999; Wheless et al. 1999; Diekmann et al. 1998; Sutherling et al. 1991; Sutherling et al. 1990; Barth et al. 1989; Sutherling et al. 1988b; Rose et al.…”
BackgroundChanging concepts in presurgical assessment for epilepsy surgery
Zijlmans, M., Zweiphenning, W., & van Klink, N. (2019) · Nature Reviews Neurology · doi:10.1038/s41582-019-0224-y · Cited by 217
Metadata
- Authors
- Wheless, J. W., Willmore, L. J., Breier, J. I., Kataki, M., Smith, J. R., King, D. W., Meador, K. J., Park, Y. D., Loring, D. W., Clifton, G. L., Baumgartner, J., Thomas, A. B., Constantinou, J. E. C., & Papanicolaou, A. C.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 1999-07
- Volume
- 40
- Issue
- 7
- Pages
- 931-941
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2029504578
- Cited by
- 193
- References
- 23
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.