Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 252

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Intracranial EEG Seizure‐Onset Patterns in Neocortical Epilepsy

Lee, Sang‐Ahm, Spencer, Dennis D., Spencer, Susan S. · 2000 · Epilepsia

Abstract

Summary: Purpose: We investigated neocortical seizure‐onset patterns recorded by intracranial EEG with regard to anatomic location, pathologic substrate, and prognostic value for surgical outcome. Methods: Seizure onset was analyzed in 53 neocortical re‐sective epilepsy surgery patients. Anatomic location was divided into temporal and extratemporal. Pathologic substrate was classified as developmental, mature, and negative or non‐specific gliosis. Onset frequency was categorized by visual analysis into tradition EEG frequency bands. Spatial extent was divided into focal (fewer than four contacts) and regional (more than five contacts). Waveform at seizure onset was divided into several types based on their morphology. Onset features were examined with respect to anatomic location, pathologic substrate, and surgical outcome. Results: Seizure‐onset frequency was significantly related to spatial distribution and to anatomic location. Extratemporal and regional onset were more commonly in the gamma range, and temporal and focal onset in the beta frequency range or slower. Waveform could be categorized into five different patterns, of which low voltage fast activity (LVFA) was the most common form (57%). LVFA and rhythmic alpha‐theta spike activity were more common in developmental than in mature pathology, whereas rhythmic sinusoidal waves at onset were found in only mature substrates. Waveform pattern showed a possible correlation with surgical outcome (p = 0.097): LVFA and rhythmic sinusoidal waves onset patterns were associated with favorable outcome more often (40.4%) than the other three patterns (6.3%). Slow onset suggested poor outcome in the subgroup of developmental pathology (p = 0.062). Conclusions: Certain electrographic seizure‐onset features are associated with specific substrates and outcomes, whereas others reflect the anatomic location and its connections independent of the pathology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1157.2000.tb00159.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 252

Metadata

Authors
Lee, S., Spencer, D. D., & Spencer, S. S.
Venue
Epilepsia
Publisher
Wiley
Published
2000-03
Volume
41
Issue
3
Pages
297-307
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2036009599
Cited by
252
References
13
FWCI
4.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intracranial EEG Seizure‐Onset Patterns in Neocortical Epilepsy. https://app.cochat.ai/papers/10.1111/j.1528-1157.2000.tb00159.x
The paper
Lee, S., Spencer, D. D., & Spencer, S. S. (2000). Intracranial EEG Seizure‐Onset Patterns in Neocortical Epilepsy. Epilepsia. https://doi.org/10.1111/j.1528-1157.2000.tb00159.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.