Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 237

The DOI matches its Crossref record.

Analysis of Chronic Seizure Onsets after Intrahippocampal Kainic Acid Injection in Freely Moving Rats

Open access
Bragin, Anatol, Azizyan, Avetis, Almajano, Joyel, Wilson, Charles L., Engel, Jerome · 2005 · Epilepsia

Abstract

Summary: Purpose: The goal of this study was to analyze the transition period between interictal and ictal activity in freely moving rats with recurrent spontaneous seizures after unilateral intrahippocampal kainic acid (KA) injection. Methods: Pairs of tungsten electrodes (50 μm O/D) were implanted bilaterally under anesthesia at symmetrical points in the dentate gyrus (DG) and CA1 regions of anterior and posterior hippocampi and entorhinal cortex of adult Wistar rats. Stimulating electrodes were placed in the right angular bundle and KA was injected into the right posterior CA3 area of hippocampus after 1 week of baseline EEG recording. Beginning 24 h after injection, electrographic activity was recorded with video monitoring for seizures every day for 8 h/day for 60 days. Results: Seventy percent of seizures started locally in the DG ipsilateral to injection, with an increase in frequency of interictal EEG spikes (hypersynchronous type, HYP), and 26% of seizures started with a decrease of EEG amplitude with parallel increase in frequency (low‐voltage fast type, LVF). During HYP seizures, a significant increase was observed in amplitude of beta‐gamma range frequencies, ripple frequency, and fast ripple (FR) frequency, whereas during LVF seizure, an increase was noted only in the beta‐gamma range. In all cases but one, an EEG wave preceded ripple and FR oscillations. Before seizure onset, the amplitude of DG‐evoked responses to single pulses decreased, whereas the amplitude of the response to the second pulse delivered at 30‐ms interval increased. Conclusions: If ripple and FR oscillations indicate the seizure‐generating neuronal substrate, these areas must be small and widespread, so that the probability of recording from them directly is very low. The decreased response to electrical stimulation before seizures could indicate a protective inhibitory mechanism that contains or prevents seizure occurrence. The presence of decreased paired‐pulse suppression could indicate a network predisposition to follow an external input with a certain frequency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1167.2005.00268.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 237

Metadata

Authors
Bragin, A., Azizyan, A., Almajano, J., Wilson, C. L., & Engel, J.
Venue
Epilepsia
Publisher
Wiley
Published
2005-09-28
Volume
46
Issue
10
Pages
1592-1598
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2010395951
Cited by
237
References
0
FWCI
3.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of Chronic Seizure Onsets after Intrahippocampal Kainic Acid Injection in Freely Moving Rats. https://app.cochat.ai/papers/10.1111/j.1528-1167.2005.00268.x
The paper
Bragin, A., Azizyan, A., Almajano, J., Wilson, C. L., & Engel, J. (2005). Analysis of Chronic Seizure Onsets after Intrahippocampal Kainic Acid Injection in Freely Moving Rats. Epilepsia. https://doi.org/10.1111/j.1528-1167.2005.00268.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.