The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
High-frequency oscillations during human focal seizures
Abstract
Discrete high-frequency oscillations (HFOs) in the range of 100-500 Hz have previously been recorded in human epileptic brains using depth microelectrodes. We describe for the first time similar oscillations in a cohort of unselected focal epileptic patients implanted with EEG macroelectrodes. Spectral analysis and visual inspection techniques were used to study seizures from 10 consecutive patients undergoing pre-surgical evaluation for medically refractory focal epilepsy. Four of these patients had focal seizure onset in the mesial temporal lobe, and in all 12 of their seizures, well-localized, segmental, very high frequency band (VHF: 250-500 Hz) oscillations were visually identified near the time of seizure onset from contacts in this zone. Increased high-frequency band (HF: 100-200 Hz) activity compared with the background was distinguished both visually and with spectral analysis later in the seizures of 3/4 mesial temporal patients, involving contacts in the generator region and, in one patient, areas of contralateral peri-hippocampal propagation. Three patients with well-defined neocortical seizure-onset areas also demonstrated focal HF or VHF oscillations confined to the seizure-onset channels during their eight seizures. No discrete HF or VHF activity was present in the poorly localized seizures from the remaining three patients. These results show that discrete HFOs can be recorded from human focal epileptic brain using depth macroelectrodes, and that they occur mostly in regions of primary epileptogenesis and rarely in regions of secondary spread. Absent high-frequency activity seems to indicate poor localization, whereas the presence of focal HFOs near the time of seizure onset may signify proximity to the epileptogenic focus in mesial temporal lobe and neocortical seizures. We postulate that focal HFOs recorded with depth macroelectrodes reflect the partial synchronization of very local oscillations such as those previously studied using microelectrodes, and result from interconnected small neuronal ensembles. Our finding that localized HFOs occur in varying anatomical structures and pathological conditions perhaps indicates commonality to diverse epileptogenic aetiologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain-state- and cell-type-specific firing of hippocampal interneurons in vivo
Klausberger, T., Magill, P. J., Márton, L. F., Roberts, J. D. B., Cobden, P. M., Buzsáki, G., & Somogyi, P. (2003) · Nature · doi:10.1038/nature01374 · Cited by 1,345
High-frequency network oscillation in the hippocampus
Buzsáki, G., Horváth, Z., Urioste, R., Hetke, J., & Wise, K. (1992) · Science · doi:10.1126/science.1589772 · Cited by 1,221
Palmini, A., Gambardella, A., Andermann, F., Dubeau, F., da Costa, J. C., Olivier, A., Tampieri, D., Gloor, P., Quesney, F., Andermann, E., et al. (1995) · Annals of Neurology · doi:10.1002/ana.410370410 · Cited by 754
Bragin, A., Engel, J., Wilson, C. L., Fried, I., & Mathern, G. W. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb02065.x · Cited by 745
Staba, R. J., Wilson, C. L., Bragin, A., Fried, I., & Engel, J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1743 · Cited by 666
Chrobak, J. J., & Buzsáki, G. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-09-03056.1996 · Cited by 587
High-frequency oscillations and seizure generation in neocortical epilepsy
Worrell, G. A., Parish, L., Cranstoun, S. D., Jonas, R., Baltuch, G., & Litt, B. (2004) · Brain · doi:10.1093/brain/awh149 · Cited by 539
High-Frequency EEG Activity at the Start of Seizures
Arroyo, S., & Uematsu, S. (1992) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199207010-00012 · Cited by 449
Traub, R. D., Whittington, M. A., Buhl, E. H., LeBeau, F. E. N., Bibbig, A., Boyd, S., Cross, H., & Baldeweg, T. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.26900.x · Cited by 368
Bragin, A., Wilson, C. L., & Engel, J. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01573.x · Cited by 359
Cited by
Neural synchrony in brain disorders: Relevance for cognitive dysfunctions and pathophysiology
Uhlhaas, P. J., & Singer, W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.020 · Cited by 2,194
Hippocampal sharp wave-ripple: A cognitive biomarker for episodic memory and planning
Buzsáki, G. (2015) · Hippocampus · doi:10.1002/hipo.22488 · Cited by 1,759
Temporal coupling of parahippocampal ripples, sleep spindles and slow oscillations in humans
Clemens, Z., Molle, M., Eross, L., Barsi, P., Halasz, P., & Born, J. (2007) · Brain · doi:10.1093/brain/awm146 · Cited by 398
Interictal scalp fast oscillations as a marker of the seizure onset zone
Andrade-Valenca, L. P., Dubeau, F., Mari, F., Zelmann, R., & Gotman, J. (2011) · Neurology · doi:10.1212/wnl.0b013e318228bee2 · Cited by 285
Akiyama, T., McCoy, B., Go, C. Y., Ochi, A., Elliott, I. M., Akiyama, M., Donner, E. J., Weiss, S. K., Snead, O. C., Rutka, J. T., et al. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03199.x · Cited by 271
Metadata
- Authors
- Jirsch, J. D.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-04-13
- Volume
- 129
- Issue
- 6
- Pages
- 1593-1608
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2131077178
- Cited by
- 533
- References
- 28
- FWCI
- 17.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-frequency oscillations during human focal seizures. https://app.cochat.ai/papers/10.1093/brain/awl085
- The paper
- Jirsch, J. D. (2006). High-frequency oscillations during human focal seizures. Brain. https://doi.org/10.1093/brain/awl085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.