CoChat

High‐Frequency Intracerebral EEG Activity (100–500 Hz) Following Interictal Spikes

Open access
Urrestarazu, Elena, Jirsch, Jeffrey D., LeVan, Pierre, Hall, Jeffery · 2006 · Epilepsia
Cited by 156

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Summary: Purpose: High‐frequency activity has been recorded with intracerebral microelectrodes in epileptic patients and related to seizure genesis. Our goal was to analyze high‐frequency activity recorded with electroencephalograph (EEG) macroelectrodes during the slow wave immediately following interictal spikes, given the potential importance of this presumed hyperpolarization in transforming spikes into seizures. Methods: Depth electrode EEG recordings from 10 patients with intractable focal epilepsy were low‐pass filtered at 500 Hz and sampled at 2,000 Hz. Spikes were categorized according to localization and morphology. Segments of 256 ms were selected immediately following (postspike), and 2 s before each spike (baseline). Power was estimated in subgamma (0–40 Hz), gamma (40–100 Hz), high frequency (100–200 Hz), and very high frequency (250–500 Hz) bands. Results: Changes in power above 100 Hz were seen in 22 of 29 spike categories, consisting primarily of a widespread decrease in frequencies above 100 Hz. This decrease became spatially more restricted as frequencies increased, and coincided with the localization of largest spikes for the highest frequencies. High‐frequency power decreases were prominent in the hippocampus but less common in amygdala and neocortex. High‐frequency power increases were observed in the amygdala. Conclusions: Thus high‐frequency EEG activity can be recorded with macroelectrodes in humans and may provide insights on neuronal mechanisms related to human epilepsy. This activity undergoes consistent modifications after EEG spikes. We propose that the reduction in high frequencies reflects a postspike depression in neuronal activity that is more pronounced in the region of spike generation. This depression is almost always seen in hippocampus but less in amygdala.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1167.2006.00618.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 156

Metadata

Authors
Urrestarazu, E., Jirsch, J. D., LeVan, P., & Hall, J.
Venue
Epilepsia
Publisher
Wiley
Published
2006-09
Volume
47
Issue
9
Pages
1465-1476
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2090243118
Cited by
156
References
3
FWCI
3.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐Frequency Intracerebral EEG Activity (100–500 Hz) Following Interictal Spikes. https://app.cochat.ai/papers/10.1111/j.1528-1167.2006.00618.x
The paper
Urrestarazu, E., Jirsch, J. D., LeVan, P., & Hall, J. (2006). High‐Frequency Intracerebral EEG Activity (100–500 Hz) Following Interictal Spikes. Epilepsia. https://doi.org/10.1111/j.1528-1167.2006.00618.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.