Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 282

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electrical Stimulation of the Anterior Nucleus of the Thalamus for Intractable Epilepsy: A Long‐term Follow‐up Study

Lim, Siew‐Na, Lee, Shih‐Tseng, Tsai, Yu‐Tai, Chen, I‐An, Tu, Po‐Hsun, Chen, Jean‐Lon, Chang, Hsiu‐Wen, Su, Yu‐Chin, Wu, Tony·2007·Epilepsia

Abstract

Summary: Purpose: The anterior nucleus of the thalamus (ANT) modulates temporal lobe and hypothalamic activities, and relays information to the cingulate gyrus and entorhinal cortex. Deep brain stimulation (DBS) of the ANT has been reported to decrease seizure activity in a limited number of human subjects. However, long‐term effect of chronic ANT stimulation on such patients remains unknown. We report long‐term follow‐up results in four patients receiving ANT stimulation for intractable epilepsy. Methods: Four patients underwent stereotactic implantation of quadripolar stimulating electrodes in the bilateral ANT, guided by single‐unit microelectrode recording. Electrode location was confirmed by postoperative magnetic resonance imaging (MRI). The stimulator was activated 2–4 weeks following electrode insertion; initial stimulation parameters were 4–5 V, 90–110 Hz, and 60–90 μs. Seizure frequency was monitored and compared with preimplantation baseline frequency. Intelligence quotient (IQ) test and auditory P300 response were performed before and after implantation of electrodes. Results: Four patients (one man with generalized seizures, and three women with partial seizures and secondary generalization) aged 18–45 years old were studied with mean follow‐up period of 43.8 months. The four patients demonstrated a sustained effect of 49% (range, 35–76%) seizure reduction to ANT stimulation. Simple insertion of DBS electrodes (Sham period, no stimulation) produced a mean reduction in seizures of 67% (range, 44–94%). One patient was seizure‐free for 15 months with anticonvulsant medications. One patient had a small frontal hemorrhage and a second patient had extension erosion over scalp; no resultant major or permanent neurological deficit was observed. Preoperative IQ index and auditory P300 were not significantly different with those after electrodes implantation. Conclusions: Implantation of electrodes in the ANT and subsequent stimulation is associated with a significant reduction in seizure frequency. However, our study could not differentiate whether the implantation itself, the subsequent stimulation or postimplantation drug manipulation had the greatest impact. These experimental results prompt further controlled study in a large patient population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1167.2006.00898.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 282

Metadata

Authors
Lim, S., Lee, S., Tsai, Y., Chen, I., Tu, P., Chen, J., Chang, H., Su, Y., & Wu, T.
Venue
Epilepsia
Publisher
Wiley
Published
2007-02
Volume
48
Issue
2
Pages
342-347
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2019418767
Cited by
282
References
1
FWCI
7.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical Stimulation of the Anterior Nucleus of the Thalamus for Intractable Epilepsy: A Long‐term Follow‐up Study. https://app.cochat.ai/papers/10.1111/j.1528-1167.2006.00898.x
The paper
Lim, S., Lee, S., Tsai, Y., Chen, I., Tu, P., Chen, J., Chang, H., Su, Y., & Wu, T. (2007). Electrical Stimulation of the Anterior Nucleus of the Thalamus for Intractable Epilepsy: A Long‐term Follow‐up Study. Epilepsia. https://doi.org/10.1111/j.1528-1167.2006.00898.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.