The DOI matches its Crossref record.
Dynamic Changes of Ictal High‐Frequency Oscillations in Neocortical Epilepsy: Using Multiple Band Frequency Analysis
Open accessAbstract
Summary: Purpose: To characterize the spatial and temporal course of ictal high‐frequency oscillations (HFOs) recorded by subdural EEG in children with intractable neocortical epilepsy. Methods: We retrospectively studied nine children (four girls, five boys; 4–17 yr) who presented with intractable extrahippocampal localization‐related epilepsy and who underwent extraoperative video subdural EEG (1000 Hz sampling rate) and cortical resection. We performed multiple band frequency analysis (MBFA) to evaluate the frequency, time course, and distribution of ictal HFOs. We compared ictal HFO changes before and after clinical onset and postsurgical seizure outcomes. Results: Seventy‐eight of 79 seizures showed HFOs. We observed wide‐band HFOs (∼250Hz, ∼120 electrodes) in six patients either with partial seizures alone (three patients) or with epileptic spasms (three patients). Three patients with partial seizures that secondarily generalized had wide‐band HFOs (∼170 Hz) before clinical onset and sustained narrow‐band HFOs (60–164 Hz) with electrodecremental events after clinical onset (∼28 electrodes). In four postoperatively seizure‐free patients, more electrodes recorded higher‐frequency HFOs inside the resection area than outside before and after clinical seizure onset. In five patients with residual seizures, electrodes recorded more HFOs that were of higher or equal frequency outside the surgical area than inside after clinical onset. Conclusion: For partial seizures alone and epileptic spasms, more electrodes recorded only wide‐band HFOs; for partial seizures that secondarily generalized, fewer electrodes recorded wide‐band HFOs, but in these seizures electrodes also recorded subsequent sustained narrow‐band ictal HFOs. Resection of those brain regions having electrodes with ictal, higher HFOs resulted in postsurgical seizure‐free outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hippocampal sharp wave-ripple: A cognitive biomarker for episodic memory and planning
Buzsáki, G. (2015) · Hippocampus · doi:10.1002/hipo.22488 · Cited by 1,759
High‐frequency electroencephalographic oscillations correlate with outcome of epilepsy surgery
Jacobs, J., Zijlmans, M., Zelmann, R., Chatillon, C., Hall, J., Olivier, A., Dubeau, F., & Gotman, J. (2010) · Annals of Neurology · doi:10.1002/ana.21847 · Cited by 673
Jacobs, J., LeVan, P., Chander, R., Hall, J., Dubeau, F., & Gotman, J. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01656.x · Cited by 634
High‐frequency oscillations as a new biomarker in epilepsy
Zijlmans, M., Jiruska, P., Zelmann, R., Leijten, F. S. S., Jefferys, J. G. R., & Gotman, J. (2012) · Annals of Neurology · doi:10.1002/ana.22548 · Cited by 524
High‐frequency oscillations: What is normal and what is not?
Engel Jr, J., Bragin, A., Staba, R., & Mody, I. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2008.01917.x · Cited by 516
Metadata
- Authors
- Ochi, A., Otsubo, H., Donner, E. J., Elliott, I., Iwata, R., Funaki, T., Akizuki, Y., Akiyama, T., Imai, K., Rutka, J. T., & Snead, O. C.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2007-02
- Volume
- 48
- Issue
- 2
- Pages
- 286-296
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1965930146
- Cited by
- 198
- References
- 0
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic Changes of Ictal High‐Frequency Oscillations in Neocortical Epilepsy: Using Multiple Band Frequency Analysis. https://app.cochat.ai/papers/10.1111/j.1528-1167.2007.00923.x
- The paper
- Ochi, A., Otsubo, H., Donner, E. J., Elliott, I., Iwata, R., Funaki, T., Akizuki, Y., Akiyama, T., Imai, K., Rutka, J. T., & Snead, O. C. (2007). Dynamic Changes of Ictal High‐Frequency Oscillations in Neocortical Epilepsy: Using Multiple Band Frequency Analysis. Epilepsia. https://doi.org/10.1111/j.1528-1167.2007.00923.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.