Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 198

The DOI matches its Crossref record.

Dynamic Changes of Ictal High‐Frequency Oscillations in Neocortical Epilepsy: Using Multiple Band Frequency Analysis

Open access
Ochi, Ayako, Otsubo, Hiroshi, Donner, Elizabeth J., Elliott, Irene, Iwata, Ryoichi, Funaki, Takanori, Akizuki, Yoko, Akiyama, Tomoyuki, Imai, Katsumi, Rutka, James T., Snead, O. Carter · 2007 · Epilepsia

Abstract

Summary: Purpose: To characterize the spatial and temporal course of ictal high‐frequency oscillations (HFOs) recorded by subdural EEG in children with intractable neocortical epilepsy. Methods: We retrospectively studied nine children (four girls, five boys; 4–17 yr) who presented with intractable extrahippocampal localization‐related epilepsy and who underwent extraoperative video subdural EEG (1000 Hz sampling rate) and cortical resection. We performed multiple band frequency analysis (MBFA) to evaluate the frequency, time course, and distribution of ictal HFOs. We compared ictal HFO changes before and after clinical onset and postsurgical seizure outcomes. Results: Seventy‐eight of 79 seizures showed HFOs. We observed wide‐band HFOs (∼250Hz, ∼120 electrodes) in six patients either with partial seizures alone (three patients) or with epileptic spasms (three patients). Three patients with partial seizures that secondarily generalized had wide‐band HFOs (∼170 Hz) before clinical onset and sustained narrow‐band HFOs (60–164 Hz) with electrodecremental events after clinical onset (∼28 electrodes). In four postoperatively seizure‐free patients, more electrodes recorded higher‐frequency HFOs inside the resection area than outside before and after clinical seizure onset. In five patients with residual seizures, electrodes recorded more HFOs that were of higher or equal frequency outside the surgical area than inside after clinical onset. Conclusion: For partial seizures alone and epileptic spasms, more electrodes recorded only wide‐band HFOs; for partial seizures that secondarily generalized, fewer electrodes recorded wide‐band HFOs, but in these seizures electrodes also recorded subsequent sustained narrow‐band ictal HFOs. Resection of those brain regions having electrodes with ictal, higher HFOs resulted in postsurgical seizure‐free outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1167.2007.00923.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
Ochi, A., Otsubo, H., Donner, E. J., Elliott, I., Iwata, R., Funaki, T., Akizuki, Y., Akiyama, T., Imai, K., Rutka, J. T., & Snead, O. C.
Venue
Epilepsia
Publisher
Wiley
Published
2007-02
Volume
48
Issue
2
Pages
286-296
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W1965930146
Cited by
198
References
0
FWCI
5.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic Changes of Ictal High‐Frequency Oscillations in Neocortical Epilepsy: Using Multiple Band Frequency Analysis. https://app.cochat.ai/papers/10.1111/j.1528-1167.2007.00923.x
The paper
Ochi, A., Otsubo, H., Donner, E. J., Elliott, I., Iwata, R., Funaki, T., Akizuki, Y., Akiyama, T., Imai, K., Rutka, J. T., & Snead, O. C. (2007). Dynamic Changes of Ictal High‐Frequency Oscillations in Neocortical Epilepsy: Using Multiple Band Frequency Analysis. Epilepsia. https://doi.org/10.1111/j.1528-1167.2007.00923.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.