Dynamic Changes of Ictal High‐Frequency Oscillations in Neocortical Epilepsy: Using Multiple Band Frequency Analysis
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: To characterize the spatial and temporal course of ictal high‐frequency oscillations (HFOs) recorded by subdural EEG in children with intractable neocortical epilepsy. Methods: We retrospectively studied nine children (four girls, five boys; 4–17 yr) who presented with intractable extrahippocampal localization‐related epilepsy and who underwent extraoperative video subdural EEG (1000 Hz sampling rate) and cortical resection. We performed multiple band frequency analysis (MBFA) to evaluate the frequency, time course, and distribution of ictal HFOs. We compared ictal HFO changes before and after clinical onset and postsurgical seizure outcomes. Results: Seventy‐eight of 79 seizures showed HFOs. We observed wide‐band HFOs (∼250Hz, ∼120 electrodes) in six patients either with partial seizures alone (three patients) or with epileptic spasms (three patients). Three patients with partial seizures that secondarily generalized had wide‐band HFOs (∼170 Hz) before clinical onset and sustained narrow‐band HFOs (60–164 Hz) with electrodecremental events after clinical onset (∼28 electrodes). In four postoperatively seizure‐free patients, more electrodes recorded higher‐frequency HFOs inside the resection area than outside before and after clinical seizure onset. In five patients with residual seizures, electrodes recorded more HFOs that were of higher or equal frequency outside the surgical area than inside after clinical onset. Conclusion: For partial seizures alone and epileptic spasms, more electrodes recorded only wide‐band HFOs; for partial seizures that secondarily generalized, fewer electrodes recorded wide‐band HFOs, but in these seizures electrodes also recorded subsequent sustained narrow‐band ictal HFOs. Resection of those brain regions having electrodes with ictal, higher HFOs resulted in postsurgical seizure‐free outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Outcome with respect to epileptic seizures.
Engel, J. (1993) · Medical Entomology and Zoology · Cited by 2,338
Presurgical evaluation of epilepsy
Rosenow, F. (2001) · Brain · doi:10.1093/brain/124.9.1683 · Cited by 1,669 · cited 1×
“The ictal onset zone itself, therefore, did not completely delineate the epileptogenic zone (Rosenow and Lüders, 2001).”
BackgroundHigh-frequency oscillations and seizure generation in neocortical epilepsy
Worrell, G. A., Parish, L., Cranstoun, S. D., Jonas, R., Baltuch, G., & Litt, B. (2004) · Brain · doi:10.1093/brain/awh149 · Cited by 539 · cited 2×
“Worrell et al. (2004) recorded HFOs at seizure onset from three to seven intracranial electrodes in patients with neocortical epilepsy.”
BackgroundSchmitz, D., Schuchmann, S., Fisahn, A., Draguhn, A., Buhl, E. H., Petrasch-Parwez, E., Dermietzel, R., Heinemann, U., & Traub, R. D. (2001) · Neuron · doi:10.1016/s0896-6273(01)00410-x · Cited by 455 · cited 2×
“Electrical coupling between principal neurons, perhaps via axonal gap junctions, might produce HFOs when seizures start (Schmitz et al., 2001; Traub et al., 2001).”
BackgroundHigh-Frequency EEG Activity at the Start of Seizures
Arroyo, S., & Uematsu, S. (1992) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199207010-00012 · Cited by 449
Local Generation of Fast Ripples in Epileptic Brain
Bragin, A., Mody, I., Wilson, C. L., & Engel, J. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-05-02012.2002 · Cited by 431 · cited 3×
“Reports from experimental studies of intracellular and extracellular recordings suggest that HFOs underlie epileptogenesis (Bragin et al., 2000; Schmitz et al., 2001; Traub et al., 2001; Bragin et al., 2002; Grenier et al., 2003).”
BackgroundTraub, R. D., Whittington, M. A., Buhl, E. H., LeBeau, F. E. N., Bibbig, A., Boyd, S., Cross, H., & Baldeweg, T. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.26900.x · Cited by 368 · cited 6×
“E-mail: ayako.ochi@sickkids.ca doi: 10.1111/j.1528-1167.2007.00923.x tra analyses showed that HFOs during the marked voltage attenuation of electrodecremental events represented ictal onset zones (Allen et al., 1992; Fisher et al., 1992; Alarcon et al., 1995; Traub et al., 2001).”
BackgroundInfluentialBragin, A., Wilson, C. L., & Engel, J. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01573.x · Cited by 359 · cited 2×
“Reports from experimental studies of intracellular and extracellular recordings suggest that HFOs underlie epileptogenesis (Bragin et al., 2000; Schmitz et al., 2001; Traub et al., 2001; Bragin et al., 2002; Grenier et al., 2003).”
BackgroundKemp, B., & Olivan, J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00123-8 · Cited by 258 · cited 1×
“We exported video subdural EEG data sections as EDF+ format files (Kemp and Olivan, 2003).”
Method
Cited by
Hippocampal sharp wave-ripple: A cognitive biomarker for episodic memory and planning
Buzsáki, G. (2015) · Hippocampus · doi:10.1002/hipo.22488 · Cited by 1,759
High‐frequency electroencephalographic oscillations correlate with outcome of epilepsy surgery
Jacobs, J., Zijlmans, M., Zelmann, R., Chatillon, C., Hall, J., Olivier, A., Dubeau, F., & Gotman, J. (2010) · Annals of Neurology · doi:10.1002/ana.21847 · Cited by 673
Jacobs, J., LeVan, P., Chander, R., Hall, J., Dubeau, F., & Gotman, J. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01656.x · Cited by 634
High‐frequency oscillations as a new biomarker in epilepsy
Zijlmans, M., Jiruska, P., Zelmann, R., Leijten, F. S. S., Jefferys, J. G. R., & Gotman, J. (2012) · Annals of Neurology · doi:10.1002/ana.22548 · Cited by 524
High‐frequency oscillations: What is normal and what is not?
Engel Jr, J., Bragin, A., Staba, R., & Mody, I. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2008.01917.x · Cited by 516
Lachaux, J.-P., Axmacher, N., Mormann, F., Halgren, E., & Crone, N. E. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.06.008 · Cited by 506
High-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
Self-citationHigh frequency oscillations in intracranial EEGs mark epileptogenicity rather than lesion type
Jacobs, J., LeVan, P., Châtillon, C.-É., Olivier, A., Dubeau, F., & Gotman, J. (2009) · Brain · doi:10.1093/brain/awn351 · Cited by 336
Akiyama, T., McCoy, B., Go, C. Y., Ochi, A., Elliott, I. M., Akiyama, M., Donner, E. J., Weiss, S. K., Snead, O. C., Rutka, J. T., et al. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03199.x · Cited by 271
Self-citationIonotropic Glutamate Receptors in Epilepsy: A Review Focusing on AMPA and NMDA Receptors
Hanada, T. (2020) · Biomolecules · doi:10.3390/biom10030464 · Cited by 249
High-frequency oscillations mirror disease activity in patients with epilepsy
Zijlmans, M., Jacobs, J., Zelmann, R., Dubeau, F., & Gotman, J. (2009) · Neurology · doi:10.1212/01.wnl.0000344402.20334.81 · Cited by 243
Ictal high frequency oscillations distinguish two types of seizure territories in humans
Weiss, S. A., Banks, G. P., McKhann, G. M., Goodman, R. R., Emerson, R. G., Trevelyan, A. J., & Schevon, C. A. (2013) · Brain · doi:10.1093/brain/awt276 · Cited by 201
“Sites with high rates of ictal HFOs correspond well with the clinically-determined seizure onset zone, which encompasses both core and penumbral territories (Ochi et al., 2007; David et al., 2011; Modur et al., 2011; Fujiwara et al., 2012; Park et al., 2012).”
Haegelen, C., Perucca, P., Châtillon, C., Andrade‐Valença, L., Zelmann, R., Jacobs, J., Collins, D. L., Dubeau, F., Olivier, A., & Gotman, J. (2013) · Epilepsia · doi:10.1111/epi.12075 · Cited by 188
“In this study, postoperative seizure outcome was worse than in other series (Cohen-Gadol et al., 2006; Ochi et al., 2007; Cossu et al., 2008; Devaux et al., 2008; Wu et al., 2010).”
BackgroundResultHigh-frequency oscillations in epileptic brain
Bragin, A., Engel, J., & Staba, R. J. (2010) · Current Opinion in Neurology · doi:10.1097/wco.0b013e3283373ac8 · Cited by 188
High-frequency oscillations in epilepsy and surgical outcome. A meta-analysis
Höller, Y., Kutil, R., Klaffenböck, L., Thomschewski, A., Höller, P. M., Bathke, A. C., Jacobs, J., Taylor, A. C., Nardone, R., & Trinka, E. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00574 · Cited by 165
“ECoG recordings Depth electrodes Study Recording Diameter Exposure Effective Diameter Surface Length surface Ochi et al., 2007 sd ECoG 4 mm – – – Jacobs et al., 2010b depth – – – 0.8 mm2 Akiyama et al., 2011 sd ECoG, depth 4 mm 2.3 mm2 4.2 mm2 8.3 mm2 van’t Klooster et al., 2011 sd ECoG, depth 4.2…”
BackgroundInfluential
Metadata
- Authors
- Ochi, A., Otsubo, H., Donner, E. J., Elliott, I., Iwata, R., Funaki, T., Akizuki, Y., Akiyama, T., Imai, K., Rutka, J. T., & Snead, O. C.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2007-02
- Volume
- 48
- Issue
- 2
- Pages
- 286-296
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1965930146
- Cited by
- 198
- References
- 24
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.