Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 539

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

High-frequency oscillations and seizure generation in neocortical epilepsy

Worrell, G. A., Parish, L., Cranstoun, S. D., Jonas, R., Baltuch, G., Litt, B.·2004·Brain

Abstract

Neocortical seizures are often poorly localized, explosive and widespread at onset, making them poorly amenable to epilepsy surgery in the absence of associated focal brain lesions. We describe, for the first time in an unselected group of patients with neocortical epilepsy, the finding that high-frequency (60-100 Hz) epileptiform oscillations are highly localized in the seizure onset zone, both before and temporally removed from seizure onset. These findings were observed in all six patients with neocortical epilepsy out of 23 consecutive patients implanted with intracranial electrodes for pre-surgical evaluation during the study period. The majority of seizures (62%) in these patients were anticipated by an increase in high-frequency activity in the 20 min prior to neocortical seizure onset. Contrary to observations in normal brain, high-frequency activity was strongly modulated by behavioural state, and was maximal during slow-wave sleep, which may explain the propensity for neocortical onset seizures to begin during sleep. These findings point to an important role for neuromodulatory circuits, probably involving the thalamus, in mechanisms underlying seizure generation in neocortical epilepsy. These findings demonstrate that high-frequency epileptiform oscillations may prove clinically useful in localizing the seizure onset zone in neocortical epilepsy, for identifying periods of increased probability of seizure onset, and in elucidating mechanisms underlying neocortical ictogenesis. Confirmation that prolonged bursts of high-frequency activity may predict focal onset neocortical seizures will require prospective validation on continuous, prolonged recordings in a larger number of patients. Importantly, the results show that the dynamic range utilized in current clinical practice for localization of epileptogenic brain largely ignores fundamental oscillations that are signatures of an epileptogenic brain. It may prove that many currently available clinical EEG systems and EEG analysis methods utilize a dynamic range that discards clinically important information.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/brain/awh149

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 539

Metadata

Authors
Worrell, G. A., Parish, L., Cranstoun, S. D., Jonas, R., Baltuch, G., & Litt, B.
Venue
Brain
Published
2004-05-20
Volume
127
Issue
7
Pages
1496-1506
ISSN
  • 0006-8950 (ISSN-L)
  • 1460-2156
OpenAlex
W1977504069
Cited by
539
References
7
FWCI
10.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-frequency oscillations and seizure generation in neocortical epilepsy. https://app.cochat.ai/papers/10.1093/brain/awh149
The paper
Worrell, G. A., Parish, L., Cranstoun, S. D., Jonas, R., Baltuch, G., & Litt, B. (2004). High-frequency oscillations and seizure generation in neocortical epilepsy. Brain. https://doi.org/10.1093/brain/awh149

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.