Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 228

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High Frequency Thalamic Stimulation for Inoperable Mesial Temporal Epilepsy

Open access
Osorio, Ivan, Overman, John, Giftakis, Jonathon, Wilkinson, Steven B. · 2007 · Epilepsia

Abstract

Summary: Purpose:To assess the safety, tolerability and efficacy of high‐frequency periodic thalamic stimulation in inoperable mesial temporal epilepsy and the usefulness of intracranially evoked responses for assessment of anatomical uniformity of lead placement. Methods:Four subjects were implanted with leads aimed at the anterior thalamic nuclei. Six weeks later, Soletra IPGs were activated using parameters similar to the closed‐loop trial's (mean: 175 Hz; 4.1 V; 90 μs; 1 min ON, 5 min OFF). Efficacy was assessed by comparing percentage change in seizure frequency over a 6‐month baseline versus a 36‐month treatment period, using a within‐subjects repeated measures design. Tolerability and safety were similarly monitored. Evoked responses elicited by thalamic stimulation were recorded from depth electrodes in the amygdalo‐hippocampal regions and compared intra and interindividually. Results:All subjects completed the study, tolerated stimulation and had no serious adverse effects. Mean reduction in seizure frequency was 75.6% (t =−8.24; p ≤ 0.01) (range: 92% to 53%). Quality of life improved in all. Verification of electrode placement with a software function indicated that stimulated structures were presumably,Anterior thalami,Latero‐polaris, Reticulatus Polaris, Ventro‐oralis Internus, and Campus Forelii. Evoked responses from stimulated sites were heterogeneous, intra and interindividually, also suggesting a lack of uniformity in lead placement. Conclusions:High‐frequency, periodic, round‐the‐clock thalamic stimulation seems safe, well tolerated and efficacious for inoperable mesial temporal epilepsy. Identification of clinically useful parameters may be facilitated by brief closed‐loop trials. Selective stimulation of a single structure may not be feasible at certain intensities, nor required for efficacy. Evoked responses may be useful for verification of uniformity of target acquisition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1167.2007.01044.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 228

Metadata

Authors
Osorio, I., Overman, J., Giftakis, J., & Wilkinson, S. B.
Venue
Epilepsia
Publisher
Wiley
Published
2007-03-26
Volume
48
Issue
8
Pages
1561-1571
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W1626618769
Cited by
228
References
1
FWCI
6.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Frequency Thalamic Stimulation for Inoperable Mesial Temporal Epilepsy. https://app.cochat.ai/papers/10.1111/j.1528-1167.2007.01044.x
The paper
Osorio, I., Overman, J., Giftakis, J., & Wilkinson, S. B. (2007). High Frequency Thalamic Stimulation for Inoperable Mesial Temporal Epilepsy. Epilepsia. https://doi.org/10.1111/j.1528-1167.2007.01044.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.