The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
830 nm laser irradiation induces varicosity formation, reduces mitochondrial membrane potential and blocks fast axonal flow in small and medium diameter rat dorsal root ganglion neurons: implications for the analgesic effects of 830 nm laser
Abstract
We report the formation of 830 nm (cw) laser‐induced, reversible axonal varicosities, using immunostaining with β‐tubulin, in small and medium diameter, TRPV‐1 positive, cultured rat DRG neurons. Laser also induced a progressive and statistically significant decrease (p < 0.005) in MMP in mitochondria in and between static axonal varicosities. In cell bodies of the neuron, the decrease in MMP was also statistically significant (p < 0.05), but the decrease occurred more slowly. Importantly we also report for the first time that 830 nm (cw) laser blocked fast axonal flow, imaged in real time using confocal laser microscopy and JC‐1 as mitotracker. Control neurons in parallel cultures remained unaffected with no varicosity formation and no change in MMP. Mitochondrial movement was continuous and measured along the axons at a rate of 0.8 μm/s (range 0.5–2 μm/s), consistent with fast axonal flow. Photoacceptors in the mitochondrial membrane absorb laser and mediate the transduction of laser energy into electrochemical changes, initiating a secondary cascade of intracellular events. In neurons, this results in a decrease in MMP with a concurrent decrease in available ATP required for nerve function, including maintenance of microtubules and molecular motors, dyneins and kinesins, responsible for fast axonal flow. Laser‐induced neural blockade is a consequence of such changes and provide a mechanism for a neural basis of laser‐induced pain relief. The repeated application of laser in a clinical setting modulates nociception and reduces pain. The application of laser therapy for chronic pain may provide a non‐drug alternative for the management of chronic pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular mechanisms of nociception
Julius, D., & Basbaum, A. I. (2001) · Nature · doi:10.1038/35093019 · Cited by 2,685 · cited 2×
“The changes occurred in the TRPV-1 positive subset of neurons, consistent with their being nociceptors, i.e., the Ad and C fibre neurons (Rang et al., 1991; Gold et al., 1996; Kress and Reeh, 1996; Julius and Basbaum, 2001; Mandadi, 2001).”
Background
Cited by
Chow, R. T., Johnson, M. I., Lopes-Martins, R. A., & Bjordal, J. M. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61522-1 · Cited by 613
Self-citationThe Use of Low Level Laser Therapy (LLLT) For Musculoskeletal Pain
B Cotler, H. (2015) · MOJ Orthopedics & Rheumatology · doi:10.15406/mojor.2015.02.00068 · Cited by 379
Effect of pulsing in low‐level light therapy
Hashmi, J. T., Huang, Y., Sharma, S. K., Kurup, D. B., De Taboada, L., Carroll, J. D., & Hamblin, M. R. (2010) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20950 · Cited by 317
Metadata
- Authors
- Chow, R. T., David, M. A., & Armati, P. J.
- Venue
- Journal of the Peripheral Nervous System
- Publisher
- Wiley
- Published
- 2007-03
- Volume
- 12
- Issue
- 1
- Pages
- 28-39
- ISSN
- 1085-9489 (ISSN-L)
- 1529-8027
- OpenAlex
- W2132455400
- Cited by
- 243
- References
- 1
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 830 nm laser irradiation induces varicosity formation, reduces mitochondrial membrane potential and blocks fast axonal flow in small and medium diameter rat dorsal root ganglion neurons: implications for the analgesic effects of 830 nm laser. https://app.cochat.ai/papers/10.1111/j.1529-8027.2007.00114.x
- The paper
- Chow, R. T., David, M. A., & Armati, P. J. (2007). 830 nm laser irradiation induces varicosity formation, reduces mitochondrial membrane potential and blocks fast axonal flow in small and medium diameter rat dorsal root ganglion neurons: implications for the analgesic effects of 830 nm laser. Journal of the Peripheral Nervous System. https://doi.org/10.1111/j.1529-8027.2007.00114.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.