Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 390

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

The Clinical Utility of a Six‐Minute Walk Test in Peripheral Arterial Occlusive Disease Patients

Montgomery, Polly S., Gardner, Andrew W.·1998·Journal of the American Geriatrics Society

Abstract

OBJECTIVES: To determine the test‐retest reliability of the distance covered and the steps taken to complete a 6‐minute walk test by peripheral arterial occlusive disease (PAOD) patients with intermittent claudication. To determine the relationship between the total distance and steps covered during the 6‐minute walk test and clinical measures of PAOD severity. DESIGN: Cross‐sectional design. SETTING: The Claude Pepper Older Americans Independence Center at the University of Maryland at Baltimore. PARTICIPANTS: Sixty‐four PAOD patients between the ages of 45 and 88 years (age = 68 ± 7 years, ankle/brachial index (ABI) = .61 ± .19) were recruited from the Vascular Clinic at the Baltimore Veterans Affairs Medical Center and from radio and newspaper advertisements. MEASUREMENTS: Patients were assessed on a 6‐minute walk test and a treadmill graded exercise test. A second 6‐minute walk test was administered approximately 1 week later. Patients also were characterized in regard to blood pressure in the arms and legs, ABI, anthropometry, body composition, and physical activity. RESULTS: The distances walked during the two 6‐minute walk tests were similar (350 ± 78 m vs 360 ± 73 m), resulting in a high reliability coefficient ( R = .94) and a low coefficient of variation (10.4%). The total steps taken during the 6‐minute walk test also were similar (562 ± 113 steps vs 587 ± 107 steps), resulting in a high reliability coefficient ( R = .90) and a low coefficient of variation (11.7%). Furthermore, the 6‐minute walking distance correlated with the distances to onset ( r = .346, P = .007) and with maximal claudication pain ( r = .525, P < .001) during the treadmill test as well as with ABI ( r = .552, P < .001). CONCLUSION: The 6‐minute walk test yields highly reliable measurements, which are related to the functional and hemodynamic severity of PAOD, in patients with intermittent claudication.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1532-5415.1998.tb03804.x

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 390

Metadata

Authors
Montgomery, P. S., & Gardner, A. W.
Venue
Journal of the American Geriatrics Society
Publisher
Wiley
Published
1998-06
Volume
46
Issue
6
Pages
706-711
ISSN
  • 0002-8614 (ISSN-L)
  • 1532-5415
OpenAlex
W1969170437
Cited by
390
References
19
FWCI
8.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Clinical Utility of a Six‐Minute Walk Test in Peripheral Arterial Occlusive Disease Patients. https://app.cochat.ai/papers/10.1111/j.1532-5415.1998.tb03804.x
The paper
Montgomery, P. S., & Gardner, A. W. (1998). The Clinical Utility of a Six‐Minute Walk Test in Peripheral Arterial Occlusive Disease Patients. Journal of the American Geriatrics Society. https://doi.org/10.1111/j.1532-5415.1998.tb03804.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.