The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Proactive administration of platelets and plasma for patients with a ruptured abdominal aortic aneurysm: evaluating a change in transfusion practice
Abstract
BACKGROUND:Continued hemorrhage remains a major contributor of mortality in massively transfused patients and those who survive have a higher platelet (PLT) count and a shorter prothrombin time and activated partial thromboplastin time (APTT) than nonsurvivors. It was considered that early substitution with PLTs and fresh‐frozen plasma (FFP) would prevent development of coagulopathy and thus improve survival. STUDY DESIGN AND METHODS:Survival of patients undergoing surgery for a ruptured abdominal aortic aneurysm (rAAA) was compared after implementing a proactive transfusion therapy encompassing two pooled buffy‐coat PLT concentrates (PBPCs) immediately when a rupture of the aorta was suspected and again 30 minutes before aortic unclamping together with FFP administered in a 1:1 ratio to the amount of red blood cells (RBCs) with that of a control group receiving transfusion therapy according to existing recommendations. RESULTS:The intervention group (n = 50) had a higher PLT count at arrival at the intensive care unit compared to the control group (n = 82; 155 × 10 9/L vs. 69 × 10 9/L; p < 0.0001), shorter APTT (39 sec vs. 44 sec; p < 0.001), fewer postoperative transfusions (RBCs, 2 vs. 6; FFP, 2 vs. 4; and PBPCs, 0 vs. 1; p < 0.01), and a higher 30‐day survival rate (66% vs. 44%; p = 0.02). CONCLUSION:This study suggests that proactive administration of PLTs and FFP improves coagulation competence, reduces postoperative hemorrhage, and increases survival in massively bleeding rAAA patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimizing the use of blood products in trauma care.
(2005) · Critical Care · doi:10.1186/cc3780 · Cited by 63
Cited by
Rossaint, R., Bouillon, B., Cerny, V., Coats, T. J., Duranteau, J., Fernández-Mondéjar, E., Filipescu, D., Hunt, B. J., Komadina, R., Nardi, G., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1265-x · Cited by 1,484
Spahn, D. R., Bouillon, B., Cerny, V., Duranteau, J., Filipescu, D., Hunt, B. J., Komadina, R., Maegele, M., Nardi, G., Riddez, L., et al. (2019) · Critical Care · doi:10.1186/s13054-019-2347-3 · Cited by 1,269
Management of bleeding and coagulopathy following major trauma: an updated European guideline
Spahn, D. R., Bouillon, B., Cerny, V., Coats, T. J., Duranteau, J., Fernández-Mondéjar, E., Filipescu, D., Hunt, B. J., Komadina, R., Nardi, G., et al. (2013) · Critical Care · doi:10.1186/cc12685 · Cited by 977
Resuscitation and transfusion principles for traumatic hemorrhagic shock
Spinella, P. C., & Holcomb, J. B. (2009) · Blood Reviews · doi:10.1016/j.blre.2009.07.003 · Cited by 368
Thachil, J., & Toh, C.-H. (2009) · Blood Reviews · doi:10.1016/j.blre.2009.04.002 · Cited by 177
Metadata
- Authors
- Johansson, P. I., Stensballe, J., Rosenberg, I., Hilsløv, T. L., Jørgensen, L., & Secher, N. H.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2007-03-22
- Volume
- 47
- Issue
- 4
- Pages
- 593-598
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W2142681490
- Cited by
- 183
- References
- 1
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proactive administration of platelets and plasma for patients with a ruptured abdominal aortic aneurysm: evaluating a change in transfusion practice. https://app.cochat.ai/papers/10.1111/j.1537-2995.2007.01160.x
- The paper
- Johansson, P. I., Stensballe, J., Rosenberg, I., Hilsløv, T. L., Jørgensen, L., & Secher, N. H. (2007). Proactive administration of platelets and plasma for patients with a ruptured abdominal aortic aneurysm: evaluating a change in transfusion practice. Transfusion. https://doi.org/10.1111/j.1537-2995.2007.01160.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.