Survival of red blood cells after transfusion: a comparison between red cells concentrates of different storage periods
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The use of fresh red blood cells (RBCs) is recommended for critically ill patients and patients undergoing surgery, although there is no conclusive evidence that this is beneficial. In this follow‐up study, the short‐term and the long‐term recovery of irradiated, leukoreduced RBCs transfused after either a short storage (SS) or a long storage (LS) period were compared. By consecutive transfusion of RBCs with a SS and LS period, a direct comparison of their survival within the same patient was possible. STUDY DESIGN AND METHODS: Ten transfusion‐requiring patients each received a SS RCCs (stored 0‐10 days) and a LS RCCs (stored 25‐35 days) consecutively. Short‐term and long‐term survival of the transfused RBCs was followed by flow cytometry using natural differences in RBC antigens between donors and patients. Posttransfusion recovery (PTR) was measured at several time points after transfusion. RESULTS: The mean 24‐hour PTR of SS RBCs is 86.4 ± 17.8 percent and that of LS RBCs 73.5 ± 13.7 percent. After the first 24 hours, the mean times to reach a PTR of 50 percent of the 24‐hour PTR (T50) and mean potential life spans (mPLs) of the surviving SS and LS RBCs (41 and 116 days and 41 and 114 days, respectively) do not differ. CONCLUSIONS: The mean 24‐hour PTR of both SS and LS RBCs complies with the guidelines, even in a compromised patient population. The 24‐hour PTR of SS RBCs, however, is significantly higher than that of LS RBCs. The remaining population of SS and LS RBCs has a nearly identical long‐term survival. Therefore, depletion of the removal‐prone RBCs before transfusion may be an efficient approach for product improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Singer, S. T., Wu, V., Mignacca, R., Kuypers, F. A., Morel, P., & Vichinsky, E. P. (2000) · Blood · doi:10.1182/blood.v96.10.3369 · Cited by 363
Effects of storage on efficacy of red cell transfusion: When is it not safe?
Ho, J., Sibbald, W. J., & Chin-Yee, I. H. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000099349.17094.a3 · Cited by 254
Van De Watering, L., Lorinser, J., Versteegh, M., Westendord, R., & Brand, A. (2006) · Transfusion · doi:10.1111/j.1537-2995.2006.00958.x · Cited by 203
Harmatz, P., Butensky, E., Quirolo, K., Williams, R., Ferrell, L., Moyer, T., Golden, D., Neumayr, L., & Vichinsky, E. (2000) · Blood · doi:10.1182/blood.v96.1.76 · Cited by 194
Nucleotide profiles of normal human blood cells determined by high-performance liquid chromatography
de Korte, D., Haverkort, W. A., Gennip, A. H., & Roos, D. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90028-4 · Cited by 101
Anaemia and red blood cell transfusion in the critically ill patient
McLellan, S. A., McClelland, D. B. L., & Walsh, T. S. (2003) · Blood Reviews · doi:10.1016/s0268-960x(03)00018-3 · Cited by 74
de Korte, D., Haverkort, W. A., Roos, D., & Gennip, A. H. (1985) · Clinica Chimica Acta · doi:10.1016/0009-8981(85)90145-7 · Cited by 71
Rapaille, A., Moore, G., Siquet, J., Flament, J., & Sondag‐Thull, D. (1997) · Vox Sanguinis · doi:10.1159/000461896 · Cited by 43
Clinical implications of red blood cell and platelet storage lesions: an overview
Solheim, B. G., Flesland, Ø., Seghatchian, J., & Brosstad, F. R. (2004) · Transfusion and Apheresis Science · doi:10.1016/j.transci.2004.09.004 · Cited by 41
Flow-Cytometric Determination of Survival Time and 24-Hour Recovery of Transfused Red Blood Cells
Zeiler, T. A., Müller, J. T., & Kretschmer, V. (2003) · Transfusion Medicine and Hemotherapy · doi:10.1159/000069340 · Cited by 23 · cited 2×
“In the past two decades, flow cytometric detection of chimerism in RBC populations has been applied for the follow-up of patients after allogeneic marrow transplantation,(12,13) to identify illicit homologous blood transfusion in athletes,(14,15) to detect and quantify fetal RBCs in fetomaternal hemorrhage,(16) and fo…”
BackgroundMethodLuten, M., Roerdinkholder‐Stoelwinder, B., Rombout‐Sestrienkova, E., DeGrip, W. J., Bos, H. J., & Bosman, G. J. C. G. M. (2007) · Transfusion · doi:10.1111/j.1537-2995.2007.01547.x · Cited by 22
Self-citation
Cited by
Hod, E. A., Zhang, N., Sokol, S. A., Wojczyk, B. S., Francis, R. O., Ansaldi, D., Francis, K. P., Della-Latta, P., Whittier, S., Sheth, S., et al. (2010) · Blood · doi:10.1182/blood-2009-10-245001 · Cited by 485
On-demand erythrocyte disposal and iron recycling requires transient macrophages in the liver
Theurl, I., Hilgendorf, I., Nairz, M., Tymoszuk, P., Haschka, D., Asshoff, M., He, S., Gerhardt, L. M. S., Holderried, T. A. W., Seifert, M., et al. (2016) · Nature Medicine · doi:10.1038/nm.4146 · Cited by 412
CD47 functions as a molecular switch for erythrocyte phagocytosis
Burger, P., Hilarius-Stokman, P., de Korte, D., van den Berg, T. K., & van Bruggen, R. (2012) · Blood · doi:10.1182/blood-2011-10-386805 · Cited by 338
Transfusion and risk of acute kidney injury in cardiac surgery
Karkouti, K. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes422 · Cited by 314
Red blood cell storage lesion: causes and potential clinical consequences.
Yoshida, T., Prudent, M., & D’Alessandro, A. (1969) · Blood transfusion · doi:10.2450/2019.0217-18 · Cited by 309
Metadata
- Authors
- Luten, M., Roerdinkholder‐Stoelwinder, B., Schaap, N. P. M., De Grip, W. J., Bos, H. J., & Bosman, G. J. C. G. M.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2008-07
- Volume
- 48
- Issue
- 7
- Pages
- 1478-1485
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W2169303083
- Cited by
- 226
- References
- 11
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.