CoChat

Reliability of capillary hemoglobin screening under routine conditions

Ziemann, Malte, Lizardo, Bettina, Geusendam, Geert, Schlenke, Peter · 2011 · Transfusion
Cited by 37

The DOI matches its Crossref record.

Abstract

BACKGROUND: Capillary hemoglobin (Hb) measurement before admission for whole blood donation is performed in many blood donation services, in spite of several studies reporting many donors with low Hb values being missed by capillary Hb screening. STUDY DESIGN AND METHODS: Predonation capillary and venous Hb levels of 9209 first‐time donors presenting for whole blood donation were compared. Hb testing was conducted by photometric determination of finger‐stick samples with a photometric method (Donor Checker, HemoCue) and using a hematology analyzer for venous samples. RESULTS: Both capillary and venous Hb measurements were available for 8910 donors (96.8%). The arithmetic mean deviation of the capillary Hb from the venous sample was +1.5 ± 6.8 g/L, and the mean deviation was 5.4 ± 4.5 g/L. In 7865 donors (88%), capillary and venous Hb values differed less than 10 g/L from each other, but in 86 donors (1.0%) the difference was at least 20 g/L, and in 10 donors (0.1%), even 30 g/L or more. In 93.3% of females and 98.7% of males, the categorization as having sufficient or too low Hb for blood donation was concordant between capillary and venous measurements. A total of 34.4% of donors with too low results of capillary Hb screening had sufficient venous Hb levels. Only one donor (0.01%) passed the capillary Hb screening despite venous Hb values below 110 g/L. CONCLUSION: The currently available methods for capillary Hb screening allow reliable determination of predonation Hb values under routine conditions. Additional venous Hb measurements in donors with too low capillary Hb values might reduce the rate of deferred donors by approximately one‐third.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1537-2995.2011.03183.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 12

  1. 10.1046/j.1537-2995.2003.00372.x · doi:10.1046/j.1537-2995.2003.00372.x
  2. 10.1111/j.1365-3148.1994.tb00275.x · doi:10.1111/j.1365-3148.1994.tb00275.x
  3. 10.1016/j.transci.2004.11.004 · DOI
  4. 10.1111/j.1537-2995.2008.02023.x · doi:10.1111/j.1537-2995.2008.02023.x
  5. 10.1016/j.transci.2010.07.010 · doi:10.1016/j.transci.2010.07.010
  6. 10.1111/j.1537-2995.2005.00574.x · doi:10.1111/j.1537-2995.2005.00574.x
  7. 10.1111/j.1537-2995.2006.01049.x · doi:10.1111/j.1537-2995.2006.01049.x
  8. 10.1046/j.1537-2995.2003.00316.x · doi:10.1046/j.1537-2995.2003.00316.x
  9. 10.1046/j.1537-2995.2001.41030353.x · doi:10.1046/j.1537-2995.2001.41030353.x
  10. 10.1111/j.1423-0410.2007.00919.x · doi:10.1111/j.1423-0410.2007.00919.x
  11. 10.1111/j.1537-2995.2006.00969.x · DOI
  12. 10.1111/j.1365-3148.2006.00693_31.x · doi:10.1111/j.1365-3148.2006.00693_31.x

Cited by

See all 37

Metadata

Authors
Ziemann, M., Lizardo, B., Geusendam, G., & Schlenke, P.
Venue
Transfusion
Publisher
Wiley
Published
2011-05-20
Volume
51
Issue
12
Pages
2714-2719
ISSN
  • 0041-1132
  • 1537-2995
Cited by
37
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of capillary hemoglobin screening under routine conditions. https://app.cochat.ai/papers/10.1111/j.1537-2995.2011.03183.x
The paper
Ziemann, M., Lizardo, B., Geusendam, G., & Schlenke, P. (2011). Reliability of capillary hemoglobin screening under routine conditions. Transfusion. https://doi.org/10.1111/j.1537-2995.2011.03183.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.