Reliability of capillary hemoglobin screening under routine conditions
The DOI matches its Crossref record.
Abstract
BACKGROUND: Capillary hemoglobin (Hb) measurement before admission for whole blood donation is performed in many blood donation services, in spite of several studies reporting many donors with low Hb values being missed by capillary Hb screening. STUDY DESIGN AND METHODS: Predonation capillary and venous Hb levels of 9209 first‐time donors presenting for whole blood donation were compared. Hb testing was conducted by photometric determination of finger‐stick samples with a photometric method (Donor Checker, HemoCue) and using a hematology analyzer for venous samples. RESULTS: Both capillary and venous Hb measurements were available for 8910 donors (96.8%). The arithmetic mean deviation of the capillary Hb from the venous sample was +1.5 ± 6.8 g/L, and the mean deviation was 5.4 ± 4.5 g/L. In 7865 donors (88%), capillary and venous Hb values differed less than 10 g/L from each other, but in 86 donors (1.0%) the difference was at least 20 g/L, and in 10 donors (0.1%), even 30 g/L or more. In 93.3% of females and 98.7% of males, the categorization as having sufficient or too low Hb for blood donation was concordant between capillary and venous measurements. A total of 34.4% of donors with too low results of capillary Hb screening had sufficient venous Hb levels. Only one donor (0.01%) passed the capillary Hb screening despite venous Hb values below 110 g/L. CONCLUSION: The currently available methods for capillary Hb screening allow reliable determination of predonation Hb values under routine conditions. Additional venous Hb measurements in donors with too low capillary Hb values might reduce the rate of deferred donors by approximately one‐third.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, capillary [Hb] can be marginally higher than that in venous blood.42–45”
From Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia (2017) · cites this paper as [44]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 12
- 10.1046/j.1537-2995.2003.00372.x · doi:10.1046/j.1537-2995.2003.00372.x
- 10.1111/j.1365-3148.1994.tb00275.x · doi:10.1111/j.1365-3148.1994.tb00275.x
- 10.1016/j.transci.2004.11.004 · DOI
- 10.1111/j.1537-2995.2008.02023.x · doi:10.1111/j.1537-2995.2008.02023.x
- 10.1016/j.transci.2010.07.010 · doi:10.1016/j.transci.2010.07.010
- 10.1111/j.1537-2995.2005.00574.x · doi:10.1111/j.1537-2995.2005.00574.x
- 10.1111/j.1537-2995.2006.01049.x · doi:10.1111/j.1537-2995.2006.01049.x
- 10.1046/j.1537-2995.2003.00316.x · doi:10.1046/j.1537-2995.2003.00316.x
- 10.1046/j.1537-2995.2001.41030353.x · doi:10.1046/j.1537-2995.2001.41030353.x
- 10.1111/j.1423-0410.2007.00919.x · doi:10.1111/j.1423-0410.2007.00919.x
- 10.1111/j.1537-2995.2006.00969.x · DOI
- 10.1111/j.1365-3148.2006.00693_31.x · doi:10.1111/j.1365-3148.2006.00693_31.x
Cited by
Otto, J. M., Plumb, J. O. M., Clissold, E., Kumar, S. B., Wakeham, D. J., Schmidt, W., Grocott, M. P. W., Richards, T., & Montgomery, H. E. (2017) · Haematologica · doi:10.3324/haematol.2017.169680 · Cited by 93
Metadata
- Authors
- Ziemann, M., Lizardo, B., Geusendam, G., & Schlenke, P.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2011-05-20
- Volume
- 51
- Issue
- 12
- Pages
- 2714-2719
- ISSN
- 0041-1132
- 1537-2995
- Cited by
- 37
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of capillary hemoglobin screening under routine conditions. https://app.cochat.ai/papers/10.1111/j.1537-2995.2011.03183.x
- The paper
- Ziemann, M., Lizardo, B., Geusendam, G., & Schlenke, P. (2011). Reliability of capillary hemoglobin screening under routine conditions. Transfusion. https://doi.org/10.1111/j.1537-2995.2011.03183.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.