Hemostats, sealants, and adhesives III: a new update as well as cost and regulatory considerations for components of the surgical toolbox
Abstract
The hemostat, sealant, and adhesive components of the surgical toolbox continue to evolve and enter clinical practice at a rapid rate. The goal of this comprehensive, sequential review is to update these components to include those now available (February 2012) as well as to explore cost and regulatory factors that impact the development and use of these materials. A unique system of definitions for organizing these components based on group, category, and class is used as a means of improving the understanding and appropriate use of these materials. The system will be used here to present the most recent additions to the toolbox, which are evaluated based on safety, efficacy, usability, and cost. These new additions include pooled human plasma fibrinogen and thrombin embedded in an equine collagen patch for cardiac surgical hemostasis, polyethylene glycol (PEG) and human serum albumin for lung surgical pneumostasis, modified PEG and trilysine amine for spinal sealing, octyl and butyl lactoyl cyanoacrylate for vascular sealing, and a variety of octyl and butyl cyanoacrylates with or without dyes and/or polyester mesh for skin closure with the creation of a bacterial barrier. The system of definitions will also be used to clarify key strategies in the current health care environment for reducing costs and for increasing understanding of Food and Drug Administration regulatory decisions for these materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Murphy, G. J., Reeves, B. C., Rogers, C. A., Rizvi, S. I. A., Culliford, L., & Angelini, G. D. (2007) · Circulation · doi:10.1161/circulationaha.107.698977 · Cited by 1,371
Cited by
Nam, S., & Mooney, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00798 · Cited by 764
Spotnitz, W. D. (2014) · ISRN Surgery · doi:10.1155/2014/203943 · Cited by 355
Self-citationTetra‐PEG Based Hydrogel Sealants for In Vivo Visceral Hemostasis
Bu, Y., Zhang, L., Sun, G., Sun, F., Liu, J., Yang, F., Tang, P., & Wu, D. (2019) · Advanced Materials · doi:10.1002/adma.201901580 · Cited by 312
Polyelectrolyte multilayered assemblies in biomedical technologies
Costa, R. R., & Mano, J. F. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60393h · Cited by 296
A highly adhesive and naturally derived sealant
Assmann, A., Vegh, A., Ghasemi-Rad, M., Bagherifard, S., Cheng, G., Sani, E. S., Ruiz-Esparza, G. U., Noshadi, I., Lassaletta, A. D., Gangadharan, S., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.06.004 · Cited by 263
Metadata
- Authors
- Spotnitz, W. D., & Burks, S.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2012-05-21
- Volume
- 52
- Issue
- 10
- Pages
- 2243-2255
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W1512810541
- Cited by
- 170
- References
- 2
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemostats, sealants, and adhesives III: a new update as well as cost and regulatory considerations for components of the surgical toolbox. https://app.cochat.ai/papers/10.1111/j.1537-2995.2012.03707.x
- The paper
- Spotnitz, W. D., & Burks, S. (2012). Hemostats, sealants, and adhesives III: a new update as well as cost and regulatory considerations for components of the surgical toolbox. Transfusion. https://doi.org/10.1111/j.1537-2995.2012.03707.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.