The Use of the Balloon‐Tipped Floating Catheter in Temporary Transvenous Cardiac Pacing
The DOI matches its Crossref record.
Abstract
The effectiveness and safety of balloon‐tipped, flow guided, electrodes for ventricular pacing as opposed to the fluoroscopy‐guided semi‐rigid bipolar electrodes have never been compared in a controlled study. A prospective study was therefore undertaken to compare both techniques in semi‐elective and emergency procedures. Flow guided electrodes were inserted in 67 patients (group A) and semi‐rigid electrodes in 44 patients (group B). The results of group A were judged to be superior to those of group B in four aspects: a) shorter insertion time (6′45″ vs. 13′30″, p < 0.0005); b) lower incidence of catheter displacement (13.4 vs. 32.0 percent, p < 0.05); c) longer interval of time between implantation and catheter displacement (4.4 vs. 1.9 days, p < 0.0005); d) lower incidence of serious ventricular arrhythmias during insertion (1.5 vs. 20.4 percent, p < 0.005). Threshold at insertion was not significantly different (0.6 ± 0.3 vs 0.7 ± 0.2 milliampere). The superiority of flow‐guided electrodes over fluoroscopy‐guided electrodes persisted in the comparison of semielective insertions in groups A and B. We conclude that the flow‐guided insertion technique is safer, more expeditious and more stable than the fluoroscopy‐guided technique in semi‐elective as well as in emergency insertions. (PACE, Vol. 4, September‐October, 1981)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.043 · Cited by 337
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000627 · Cited by 160
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- LANG, R., DAVID, D., KLEIN, H. O., DI SEGNI, E., LIBHABER, C., SARELI, P., & KAPLINSKY, E.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1981-09
- Volume
- 4
- Issue
- 5
- Pages
- 491-495
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2049781430
- Cited by
- 37
- References
- 0
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.