Effect of the Antiarrhythmic Agent Flecainide Acetate on Acute and Chronic Pacing Thresholds
The DOI matches its Crossref record.
Abstract
To determine the effect of flecainide acetate, a Class IG antiarrnythmic drug, the medication was given to 28 patients with ventricular pacing electrodes. Eleven patients with temporary pacing electrodes (Group I) received intravenous flecainide (2 mg/kg over 10 minutes). Ten patients with chronic permanent electrodes (Group II) were given the same dose at the time of elective pulse generator change. Seven, with implanted multiprogrammable pacemakers capable of threshold analysis (Group III), were given intravenous flecainide and 5 of these were then given the drug orally for up to 3 weeks (100 mg/day increasing to 400 mg/day). In Group I the threshold measured at a pulse width of 0.5 ms rose from a control value of 0.66 to 1.44 volts after 10 minutes (p < 0.01). In Group II the threshold rose from 1.73 to 2.13 volts (p < 0.01) and 2 patients had total suppression of their ventricular escape rhythm for approximately one hour. In Group III patients, intravenous flecainide resulted in a rise of the pulse width threshold measured at 2.7 volts from 0.14 to 0.22 ms (p<0.02) and at 4.9 volts from 0.06 to 0.11 ms (p<0.05) after 10 minutes. After 3 weeks of oral therapy the threshold at 2.7 volts had risen from 0.09 to 0.28 ms (p < 0.02) and al 4.9 volts from 0.06 to 0.16 ms (p< 0.05). Flecainide significantly increased both acute and chronic thresholds and the most marked rise (> 200%) occurred during chronic oral therapy. Both intravenous and oral flecainide should be used with care in patients with either temporary or permanent pacing systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Myerburg, R. J., Quinones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,973
Self-citationAl-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,854
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Writing Committee Members, Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., et al. (2006) · Europace · doi:10.1093/europace/eul108 · Cited by 738
Self-citation
Metadata
- Authors
- HELLESTRAND, K. J., BURNETT, P. J., MILNE, J. R., BEXTON, R. S., NATHAN, A. W., & CAMM, A. J.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1983-07
- Volume
- 6
- Issue
- 4
- Pages
- 892-899
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2066015294
- Cited by
- 85
- References
- 0
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of the Antiarrhythmic Agent Flecainide Acetate on Acute and Chronic Pacing Thresholds. https://app.cochat.ai/papers/10.1111/j.1540-8159.1983.tb04410.x
- The paper
- HELLESTRAND, K. J., BURNETT, P. J., MILNE, J. R., BEXTON, R. S., NATHAN, A. W., & CAMM, A. J. (1983). Effect of the Antiarrhythmic Agent Flecainide Acetate on Acute and Chronic Pacing Thresholds. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1983.tb04410.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.