Holter Documented Sudden Death in a Patient with an Implanted Defibrillator
The DOI matches its Crossref record.
Abstract
A 68‐year‐old man with recurrent attacks of monomorphic ventricular tachycardia (VT) received a pacer cardioverter defifarillalor featuring antitachycardia pacing and cardioversion/defibrillation. Over 300 episodes of VT were successfully terminated by antitachycardia pacing. During Holter monitoring the patient experienced supra ventricular tachycardia with delivery of multiple antitachycardia pacing, cardioversion, and defibrillation therapies ending with the death of the patient. The following factors played a role in the unfortunate outcome of this patient: 1. triggering of VT therapy by an unexpected high sinus rate; 2. atrial fibrillation induced by cardioversion therapy; 3, a gradual and continuous increase in rate during atrial fibrillation possibly caused by repeated VT and ventricular fibrillation therapies and/or by a thrombus, found at autopsy, in a bypass graft; and 4. the limited ability of presently available defibrillators to distinguish between ventricular and supraventricular arrhythmias.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Myerburg, R. J., Quinones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,973
Writing Committee Members, Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., et al. (2006) · Europace · doi:10.1093/europace/eul108 · Cited by 738
ACC/AHA guidelines for ambulatory electrocardiography
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00354-x · Cited by 309
Kadish, A. H., Buxton, A. E., Kennedy, H. L., Knight, B. P., Mason, J. W., Schuger, C. D., Tracy, C. M., Winters, W. L., Boone, A. W., Elnicki, M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01680-1 · Cited by 244
Committee Members, Kadish, A. H., Buxton, A. E., Kennedy, H. L., Knight, B. P., Mason, J. W., Schuger, C. D., Tracy, C. M., Winters, W. L., Boone, A. W., et al. (2001) · Circulation · doi:10.1161/circ.104.25.3169 · Cited by 192
Metadata
- Authors
- BIRGERSDOTTER‐GREEN, U., ROSENQVIST, M., LINDEMANS, F. W., RYDÉN, L., & RADEGRAN, K.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1992-07
- Volume
- 15
- Issue
- 7
- Pages
- 1008-1014
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2162317519
- Cited by
- 51
- References
- 0
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Holter Documented Sudden Death in a Patient with an Implanted Defibrillator. https://app.cochat.ai/papers/10.1111/j.1540-8159.1992.tb03094.x
- The paper
- BIRGERSDOTTER‐GREEN, U., ROSENQVIST, M., LINDEMANS, F. W., RYDÉN, L., & RADEGRAN, K. (1992). Holter Documented Sudden Death in a Patient with an Implanted Defibrillator. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1992.tb03094.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.