The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
The Biophysics of Radiofrequency Catheter Ablation in the Heart: The Importance of Temperature Monitoring
Abstract
Radiofrequency (RF) catheter ablation is a technique whereby high frequency alternating electrical current with frequencies of 350 kHz to 1 MHz is delivered through eiectrode catheters to myocardial tissue creating a thermal lesion. The mechanism by which RF current heats tissue is resistive (or ohmic) heating of a narrow rim (< 1 mm) of tissue that is in direct contact with the electrode Deeper tissue planes are then heated by conduction from the small region of volume heating. Heat is dissipated from the region by further heat conduction into normothermic tissue, and by heat convection via the circulating blood pool and larger coronary vessels. The lesion size is proportional to the temperature at the electrode‐tissue interface (which is also a function of power level if electrical factors remain constant), and to the size of the electrode. At temperatures above 100°C, boiling occurs at the electrode‐tissue contact point resulting in a rapid rise in electrical impedance. Therefore, a theoretical maximum lesion size exists for any given electrode geometry. Other factors that are important for RF lesion formation incude electrode‐tissue contact pressure and duration of RF delivery. Temperature rises monoexponentially, and duration of energy delivery should be at least 35 to 45 seconds to approach steady state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Calkins, H., Sousa, J., El-Atassi, R., Rosenheck, S., de Buitleir, M., Kou, W. H., Kadish, A. H., Langberg, J. J., & Morady, F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242302 · Cited by 698
Differential response of normal and tumor microcirculation to hyperthermia.
Dudar, T. E., & Jain, R. K. (1984) · PubMed · Cited by 307
HAINES, D. E. (1991) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1991.tb01353.x · Cited by 264
Self-citationCell poration and cell fusion using an oscillating electric field
Chang, D. C. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82711-0 · Cited by 214
Jackman, W. M., Wang, X. Z., Friday, K. J., Fitzgerald, D. M., Roman, C., Moulton, K., Margolis, P. D., Bowman, A. J., Kuck, K. H., & Naccarelli, G. V. (1991) · Circulation · doi:10.1161/01.cir.83.5.1562 · Cited by 178
Ultrastructural injury to chick myocardial cells in vitro following "electric countershock".
Jones, J. L., Proskauer, C. C., Paull, W. K., et al. (1980) · Circulation Research · doi:10.1161/01.res.46.3.387 · Cited by 93
Ring, M. E., Huang, S. K. S., Gorman, G. D., & Graham, A. R. (1989) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1989.tb06155.x · Cited by 75
Cited by
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Metadata
- Authors
- HAINES, D. E.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1993-03
- Volume
- 16
- Issue
- 3
- Pages
- 586-591
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2095695934
- Cited by
- 287
- References
- 8
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Biophysics of Radiofrequency Catheter Ablation in the Heart: The Importance of Temperature Monitoring. https://app.cochat.ai/papers/10.1111/j.1540-8159.1993.tb01630.x
- The paper
- HAINES, D. E. (1993). The Biophysics of Radiofrequency Catheter Ablation in the Heart: The Importance of Temperature Monitoring. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1993.tb01630.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.