Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 264

The DOI matches its Crossref record.

Determinants of Lesion Size During Radiofrequency Catheter Ablation: The Role of Electrode‐Tissue Contact Pressure and Duration of Energy Delivery

HAINES, DAVID E.·1991·Journal of Cardiovascular Electrophysiology

Abstract

Determinants of Radiofrequency Lesion Size. Introduction: Radiofrequency (RF) catheter ablation is a promising modality in the management of cardiac arrhythmias, but the optimum protocol for energy delivery has not yet been determined. The purpose of this study was to examine the effects of varying electrode‐tissue contact pressure and varying duration of RF energy delivery on the size of the resultant lesion in an in vitro model of isolated perfused and superfused canine myocardium. Methods and Results: RF power (500 kHz) was delivered through the tip of a specially‐designed thermistor‐tipped 1.6‐mm diameter electrode mounted on an adjustable fulcrum so that contact force could be varied. RF power was adjusted to maintain a constant electrode‐tissue interface temperature of 80°C during lesion production. Seventy‐nine lesions were created with a 90‐second RF energy delivery, and a contact force that was varied between 0 and 400 newtons (N) (0‐41 g). Lesions produced with a small contact force (10 N) were significantly larger than those with a contact force of zero (width 5.5 mm vs 3.8 mm, P <0.0002), but not significantly different from those produced with the maximum contact force of 400 N (width 6.5 mm, P = NS). However, the greater contact force significantly decreased the power required to maintain a constant electrode‐tissue interface temperature. Ninety‐six lesions were then created using a constant contact force, but duration of energy delivery was varied from 10 to 600 seconds. Lesion size grew monoexponentially with time. The t 1/2 of lesion growth was 7.6 and 9.6 seconds for depth and width, respectively. Conclusion: Thus, close electrode‐tissue contact is essential for adequate lesion formation during RF ablation of myocardium, but increasing contact force does not significantly increase lesion size if power is adjusted to maintain a constant electrode‐tissue interface temperature. In order to approach steady‐state and maximize lesion size, duration of RF energy delivery should be at least 40 seconds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1991.tb01353.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 264

Metadata

Authors
HAINES, D. E.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1991-12
Volume
2
Issue
6
Pages
509-515
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1995216474
Cited by
264
References
0
FWCI
6.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determinants of Lesion Size During Radiofrequency Catheter Ablation: The Role of Electrode‐Tissue Contact Pressure and Duration of Energy Delivery. https://app.cochat.ai/papers/10.1111/j.1540-8167.1991.tb01353.x
The paper
HAINES, D. E. (1991). Determinants of Lesion Size During Radiofrequency Catheter Ablation: The Role of Electrode‐Tissue Contact Pressure and Duration of Energy Delivery. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1991.tb01353.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.