Sinus Node Modification Using Radiofrequency Current in a Patient with Persistent Inappropriate Sinus Tachycardia
The DOI matches its Crossref record.
Abstract
Radiofrequency catheter modification of the sinus node for persistent inappropriate sinus tachycardia has not been previously reported. This article describes a patient in whom radiofrequency current was used to ablate an incessant automatic tachycardia focus mapped to the region of the sinus node, where a discrete multicomponent electrogram demonstrating earliest atrial activation was recorded. A transient junctional rhythm developed immediately after ablation, with rapid subsequent emergence of a stable rhythm having normal sinus nodal characteristics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
Radiofrequency catheter ablation of inappropriate sinus tachycardia guided by activation mapping
Man, K. C., Knight, B., Tse, H.-F., Pelosi, F., Michaud, G. F., Flemming, M., Strickberger, S. A., & Morady, F. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00546-x · Cited by 142
Inappropriate Sinus Tachycardia: Evaluation and Therapy
KRAHN, A. D., YEE, R., KLEIN, G. J., & MORILLO, C. (1995) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1995.tb00391.x · Cited by 110
Three-dimensional nonfluoroscopic mapping and ablation of inappropriate sinus tachycardia
Marrouche, N. F., Beheiry, S., Tomassoni, G., Cole, C., Bash, D., Dresing, T., Saliba, W., Abdul-Karim, A., Tchou, P., Schweikert, R., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01703-5 · Cited by 105
Sinus tachyarrhythmias and the specific bradycardic agents: a marriage made in heaven?
Yusuf, S., & Camm, A. J. (2003) · Journal of Cardiovascular Pharmacology and Therapeutics · doi:10.1177/107424840300800202 · Cited by 48
Metadata
- Authors
- WASPE, L. E., CHIEN, W. W., MERILLAT, J. C., & STARK, S. I.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 17
- Issue
- 9
- Pages
- 1569-1576
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2056324228
- Cited by
- 18
- References
- 0
- FWCI
- 0.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sinus Node Modification Using Radiofrequency Current in a Patient with Persistent Inappropriate Sinus Tachycardia. https://app.cochat.ai/papers/10.1111/j.1540-8159.1994.tb01525.x
- The paper
- WASPE, L. E., CHIEN, W. W., MERILLAT, J. C., & STARK, S. I. (1994). Sinus Node Modification Using Radiofrequency Current in a Patient with Persistent Inappropriate Sinus Tachycardia. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1994.tb01525.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.