CoChat

Early Complications After Dual Chamber Versus Single Chamber Pacemaker Implantation

CHAUHAN, A., GRACE, A.A., NEWELL, S.A., STONE, D.L., SHAPIRO, L.M., SCHOFIELD, P.M., PETCH, M.C. · 1994 · Pacing and Clinical Electrophysiology
Cited by 217

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This study was performed to compare the frequency of early complications after single chamber versus dual chamber permanent pacemaker implantation. Early complication was defined as one occurring in the 6‐week period following implantation. We prospectively analyzed consecutive pacemaker implantation from January 1987 to June 1993 at our regional center. All complications were also analyzed for the relationship to operator experience, the venous access route, and the presence of temporary pacing wire at the time of implantation of the permanent pacing system. A total of 2019 new pacemaker units were implanted during this period. 1733 patients (85.8%) received a VVI pacemaker and 286 (14.2%) a DDD unit. Wound infection occurredin 11 (0.6%) VVI patients and 6 (2.1%) DDD patients. Lead displacement occurred in 18(1 %) VVI patients and 15 (5.2%) DDD patients (11 [3.8%] atrial and 4 [1.4 %] ventricular). There were 10 (0.6%)pneumothoraces, 9 (0.5%) hematomas requiring drainage, 1 (0.06%) chylocele, and 2 (0.1%) deaths in the VVI group. There were 2 (0.7%) pneumothoraces, 2 (0.7%) hematomas, and no deaths in the DDD group. There was no significant increase in complications for experienced infrequent implanters (< 12 systems per year). In both groups the subclavian approach was associated with a risk of pneumothorax when compared to the cephalic approach. The rate of wound infection was higher in patients who had a temporary pacing wire in place. The use of prophylactic antibiotics does not appear to affect the incidence of wound infection. The early complications in the DDD group were higher than in the VVI group (8.7% vs 2.9%, P < 0.05), being mainly due to an increased incidence of wound infection and atrial lead displacement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1994.tb03791.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 7

  1. 10.1111/j.1540-8159.1982.tb02281.x · doi:10.1111/j.1540-8159.1982.tb02281.x
  2. Scheibelhofer W, 1981, Complications of physiologic pacing, PACE, 40, A
  3. 10.1111/j.1540-8159.1990.tb02095.x · doi:10.1111/j.1540-8159.1990.tb02095.x
  4. 10.1016/S0003-4975(10)62705-1 · doi:10.1016/s0003-4975(10)62705-1
  5. 10.1111/j.1540-8159.1986.tb06600.x · doi:10.1111/j.1540-8159.1986.tb06600.x
  6. 10.1056/NEJM198505303122205 · doi:10.1056/nejm198505303122205
  7. Winner SJ, 1989, Hazzards associated with the use of temporary pacemakers before permanent pacing, Br Heart J, 61, 96P

Cited by

See all 217

Metadata

Authors
CHAUHAN, A., GRACE, A. A., NEWELL, S. A., STONE, D. L., SHAPIRO, L. M., SCHOFIELD, P. M., & PETCH, M. C.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1994-11
Volume
17
Issue
11
Pages
2012-2015
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1989630240
Cited by
217
References
1
FWCI
2.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.