The Impact of the Implantable Cardioverter Defibrillator on Quality‐of‐Life
The DOI matches its Crossref record.
Abstract
The implantable Cardioverter defibrillator (ICD) is an established treatment for patients with life‐threatening ventricular arrhythmias. While it clearly reduces the incidence of death from recurrent arrhythmia, little is known about the impact on patients' quality‐of‐life. In this prospective study, quality‐of‐life was assessed by questionnaire before and after ICD implantation. The “Sickness Impact Profile” (SIP), which evaluates physical, psychosocial, and other activities, as well as functions of daily life, was used. Employment and rehospitalization rates were also examined. Twenty‐one of 23 consecutive patients, aged 58 ± 11 years, undergoing ICD implantation at Royal Perth Hospital were studied. During the 14 ± 8 month follow‐up, 4 patients died. Functional capacity was unchanged in all but one of the survivors in whom it improved from New York Heart Association Class III to II. Four of 8 survivors employed before implant have since retired. Six patients required rehospitalization on 13 occasions, problems related to arrhythmias or the ICD. Overall SIP scores preimplant (11.2 ± 9.3; P < 0.05) were significantly worse at 6‐month follow‐up (21.7 ± 18.2), but returned to preimplant levels by 12‐month follow‐up (8.8 ± 10.8; NS). This was primarily due to transient problems in the areas of emotional behavior, alertness, and social interaction. SIP psychosocial dimension scores: preimplant: 7.2 ± 9.0; 6‐month: 17.8 ± 18.1 (P < 0.05); and 12‐month: 8.6 ± 10.3 (NS). Early retirement and hospitalizations due to arrhythmias may still be expected even after implantation of an ICD; however, quality‐of‐life appears only to temporarily decline.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
QUALITY OF LIFE AND PSYCHOLOGICAL FUNCTIONING OF ICD PATIENTS
Sears, S. F., & Conti, J. B. (2002) · Heart · doi:10.1136/heart.87.5.488 · Cited by 395
Examining the psychosocial impact of implantable cardioverter defibrillators: A literature review
Camm, A. J., Sears, S. F., Todaro, J. F., Lewis, T. S., Sotile, W., & Conti, J. B. (1999) · Clinical Cardiology · doi:10.1002/clc.4960220709 · Cited by 292
Pedersen, S. S., van Domburg, R. T., Theuns, D. A. M. J., Jordaens, L., & Erdman, R. A. M. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.06.031 · Cited by 152
Psychopathology in Patients with ICDs over Time: Results of a Prospective Study
KAPA, S., ROTONDI-TREVISAN, D., MARIANO, Z., AVES, T., IRVINE, J., DORIAN, P., & HAYES, D. L. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02599.x · Cited by 112
Metadata
- Authors
- MAY, C. D., SMITH, P. R., MURDOCK, C. J., & DAVIS, M. J. E.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1995-07
- Volume
- 18
- Issue
- 7
- Pages
- 1411-1418
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2155261057
- Cited by
- 133
- References
- 0
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Impact of the Implantable Cardioverter Defibrillator on Quality‐of‐Life. https://app.cochat.ai/papers/10.1111/j.1540-8159.1995.tb02603.x
- The paper
- MAY, C. D., SMITH, P. R., MURDOCK, C. J., & DAVIS, M. J. E. (1995). The Impact of the Implantable Cardioverter Defibrillator on Quality‐of‐Life. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1995.tb02603.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.