CoChat

ECG Criteria to Distinguish Between Aberrantly Conducted Supraventricular Tachycardia and Ventricular Tachycardia:Practical Aspects for the Immediate Care Setting

DREW, BARBARA J., SCHEINMAN, MELVIN M. · 1995 · Pacing and Clinical Electrophysiology
Cited by 71

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

To reevaluate ECG criteria for distinguishing Supraventricular tachycardia (SVT) with aberrant conduction from ventricular tachycardia (VT), 133 wide QRS tachycardias were recorded in patients undergoing invasive electrophysiological (EP) study. Surface ECG leads (standard 12‐lead and MCL leads) were compared to EP recordings to provide a standard for correct diagnosis. Criteria from six studies were pooled to select QRS morphology agreed to be highly specific for SVT or VT (specificity > 90%). Some morphological criteria were modified to simplify analysis for the immediate care setting. Results: Although the 12‐lead ECG was useful in distinguishing aberrancy from VT, 13 tachycardias (10%) were misdiagnosed or could not be diagnosed. The MCL 1 lead recorded clearly different QRS morphology than lead V 1 in 40% of VT cases and was diagnostically inferior to V 1.Most established criteria were highly specific for a diagnosis, but not very sensitive as individual criteria. Neither a QRS width of > 0.14 seconds nor a monophasic R wave pattern in lead V 1 were valuable in diagnosing VT. Conclusions: In distinguishing SVT with aberrant conduction from VT: (1) Although the 12‐lead ECG is valuable, about 1 in 10 wide QRS tachycardias defy differentiation; (2) tachycardias > 190 beats/mm often do not exhibit unequivocal criteria with which to make a certain diagnosis; (3) multiple leads are required for accurate assessment of QRS width, presence of AV dissociation or VA block, QRS axis, and morphological criteria; and (4) the MCL 1 lead cannot be substituted for V 1 in the use of morphological criteria for VT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1995.tb04647.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 71

Metadata

Authors
DREW, B. J., & SCHEINMAN, M. M.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1995-12
Volume
18
Issue
12
Pages
2194-2208
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2083445503
Cited by
71
References
4
FWCI
1.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ECG Criteria to Distinguish Between Aberrantly Conducted Supraventricular Tachycardia and Ventricular Tachycardia:Practical Aspects for the Immediate Care Setting. https://app.cochat.ai/papers/10.1111/j.1540-8159.1995.tb04647.x
The paper
DREW, B. J., & SCHEINMAN, M. M. (1995). ECG Criteria to Distinguish Between Aberrantly Conducted Supraventricular Tachycardia and Ventricular Tachycardia:Practical Aspects for the Immediate Care Setting. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1995.tb04647.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.