CoChat

Atrial Flutter Mapping and Ablation II. Radiofrequency Ablation of Atrial Flutter Circuits

Barol, S. Serge, COSIO, FRANCISCO G., ARRIBAS, FERNANDO, LÓPEZ‐GIL, MARÍA, GONZÁLEZ, H. DANIEL · 1996 · Pacing and Clinical Electrophysiology
Cited by 47

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The definition of the anatomical substrate of reentry in at rial flutter has allowed the recognition of narrow, critical areas of the circuit, where radiofrequencv ablation can interrupt reentry. In common flutter the isthmus between the inferior vena cava and the tricuspid valve appears the best target, but ablation between the coronary sinus and tricuspid valve can also be effective in some cases. In atypical flutter using the same circuit as common flutter in a “clockwise” direction, ablation of the same isthmus is effective. Flutter interruption is the main objective, but it does not mean complete isthmus ablation. If flutter remains inducible, new applications are delivered in the isthmus, until it is made noninducible. Complications are rare. Despite attaining noninducibility, flutter may recur, and new procedures may he needed to prevent recurrence. Atrial fibrillation can occur in up to 30% of the cases during follow‐up, but it is generally well controlled with antiarrhythmic drugs, that were ineffective to treat flutter before ablation. In reentry circuits based on surgical atrial scars, ablation of an isthmus between the scar and the inferior vena cava can also be effective. Left atrial circuits are not known well enough to guide successful ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1996.tb03394.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 47

Metadata

Authors
Barol, S. S., COSIO, F. G., ARRIBAS, F., LÓPEZ‐GIL, M., & GONZÁLEZ, H. D.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1996-06
Volume
19
Issue
6
Pages
965-975
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2137476079
Cited by
47
References
2
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Atrial Flutter Mapping and Ablation II. Radiofrequency Ablation of Atrial Flutter Circuits. https://app.cochat.ai/papers/10.1111/j.1540-8159.1996.tb03394.x
The paper
Barol, S. S., COSIO, F. G., ARRIBAS, F., LÓPEZ‐GIL, M., & GONZÁLEZ, H. D. (1996). Atrial Flutter Mapping and Ablation II. Radiofrequency Ablation of Atrial Flutter Circuits. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1996.tb03394.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.