The Effect of Ventricular Activation Sequence on Cardiac Performance During Pacing
The DOI matches its Crossref record.
Abstract
The aim of this study was to evaluate the importance of a normal ventricular activation pattern for cardiac performance. In nine mongrel clogs, atrial pacing was compared to AV synchronous pacing at three different A V delays (150, 100, and 60 nis). In six dogs, proximal septal AV synchronous pacing was compared to apical A V synchronous pacing at three different A V delays. AV synchronous pacing was performed after RF induced complete heart block. Hemodynarnics were evaluated by assessment of positive and negative dP/dt, cardiac output, and left ventricular and pulmonary pressures. Atrial pacing was superior to AV synchronous pacing with respect to positive and negative dP/dt and cardiac output. This difference was present at all AV delays. Proximal septal pacing was associated with a higher positive and negative dP/dl compared to apical pacing at all AV delays. Left ventricular activation time was significantly shorter during proximal septal pacing than during apical pacing (88 ± 4 vs 115 ± 4 ms, P < 0.001). We conclude that atrial and proximal septal pacing improves cardiac function and shortens the ventricular activation time compared to apical AV synchronous pacing independent of the AV interval.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Deshmukh, P., Casavant, D. A., Romanyshyn, M., & Anderson, K. (2000) · Circulation · doi:10.1161/01.cir.101.8.869 · Cited by 770
Prinzen, F. W., Hunter, W. C., Wyman, B. T., & McVeigh, E. R. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00068-6 · Cited by 672
Nielsen, J. C., Kristensen, L., Andersen, H. R., Mortensen, P. T., Pedersen, O. L., & Pedersen, A. K. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00757-5 · Cited by 506
Metadata
- Authors
- ROSENQVIST, M., BERGFELDT, L., HAGA, Y., RYDÉN, J., RYDÉN, L., & ÖWALL, A.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1996-09
- Volume
- 19
- Issue
- 9
- Pages
- 1279-1286
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2090690414
- Cited by
- 146
- References
- 0
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of Ventricular Activation Sequence on Cardiac Performance During Pacing. https://app.cochat.ai/papers/10.1111/j.1540-8159.1996.tb04205.x
- The paper
- ROSENQVIST, M., BERGFELDT, L., HAGA, Y., RYDÉN, J., RYDÉN, L., & ÖWALL, A. (1996). The Effect of Ventricular Activation Sequence on Cardiac Performance During Pacing. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1996.tb04205.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.