CoChat

A Randomized, Single‐Blind Crossover Comparison of the Effects of Chronic DDD and Dual Sensor VVIR Pacing Mode on Quality‐of‐ Life and Cardiopulmonary Performance in Complete Heart Block

DEHARO, JEAN‐CLAUDE, BADIER, MONIQUE, THIRION, XAVIER, RITTER, PHILIPPE, PROVENIER, FRANK, GRAUX, PIERRE, GUILLOT, CHANTAL, MUGICA, JACQUES, JORDAENS, LUC, DJIANE, PIERRE · 1996 · Pacing and Clinical Electrophysiology
Cited by 24

The DOI matches its Crossref record.

Abstract

The aim of this study was to compare DDD and dual sensor VVIR (activity and QT) pacing modes in complete AV block (CAVB). Eighteen patients (14 men and 4 women, aged 70 ± 6.5 years) implanted with a dual chamber, dual sensor pacemaker for CAVB with normal sinus node chronotropic function were studied. A quality‐of‐life and cardiovascular symptom questionnaire, and a treadmill exercise test were completed after a period of VVIR and a period of DDD pacing, each lasting 1 month. Overall quality‐of‐life and cardiovascular symptoms did not significantly differ, though three patients felt discomfort during VVIR mode. There was no significant statistical difference in Cardiopulmonary parameters. DDD and VVIR modes yielded the following respective data: maximum heart rate = 105.7 ± 21.8 beats/minute versus 107.6 ± 21.6 beats/minute (NS); maximum workload = 60 ± 33.4 W versus 59.3 ± 37.8 W (NS); treadmill duration = 10.1 ± 3.8 minute versus 10.1 ± 3.6 minute (NS); oxygen consumption at anaerobic threshold = 14.6 ± 4.1 ml/kg per minute versus 14.9 ± 4.6 mL/kg per minute (NS); maximum minute ventilation = 49.6 ± 9 L/min versus 46 ± 12 L/min (NS); and respiratory quotient = 1.08 ± 0.15 versus 1.08 ± 0.13 (NS). We conclude that, during a 1‐month follow‐up period, no difference was found between DDD and dual sensor VVIR (QT and activity) pacing modes in CAVB patients with regard to quality‐of‐life and Cardiopulmonary performance, though a trend toward an increased sense of well being was noted with the DDD mode.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1996.tb04210.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 24

Metadata

Authors
DEHARO, J., BADIER, M., THIRION, X., RITTER, P., PROVENIER, F., GRAUX, P., GUILLOT, C., MUGICA, J., JORDAENS, L., & DJIANE, P.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1996-09
Volume
19
Issue
9
Pages
1320-1326
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2153831687
Cited by
24
References
0
FWCI
1.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Randomized, Single‐Blind Crossover Comparison of the Effects of Chronic DDD and Dual Sensor VVIR Pacing Mode on Quality‐of‐ Life and Cardiopulmonary Performance in Complete Heart Block. https://app.cochat.ai/papers/10.1111/j.1540-8159.1996.tb04210.x
The paper
DEHARO, J., BADIER, M., THIRION, X., RITTER, P., PROVENIER, F., GRAUX, P., GUILLOT, C., MUGICA, J., JORDAENS, L., & DJIANE, P. (1996). A Randomized, Single‐Blind Crossover Comparison of the Effects of Chronic DDD and Dual Sensor VVIR Pacing Mode on Quality‐of‐ Life and Cardiopulmonary Performance in Complete Heart Block. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1996.tb04210.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.