Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 631

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Quality of Life and Clinical Outcomes in Elderly Patients Treated with Ventricular Pacing as Compared with Dual-Chamber Pacing

Open access
Lamas, Gervasio A., Orav, E. John, Stambler, Bruce S., Ellenbogen, Kenneth A., Sgarbossa, Elena B., Huang, Shoei K. Stephen, Marinchak, Roger A., Estes, N.A. Mark, Mitchell, Gary F., Lieberman, Eric H., Mangione, Carol M., Goldman, Lee, Griffin, John J., Maloney, James D., Rizo-Patrón, Carlos, Venditti, Ferdinand J., Wilkoff, Bruce L.·1998·New England Journal of Medicine

Abstract

BACKGROUND: Standard clinical practice permits the use of either single-chamber ventricular pacemakers or dual-chamber pacemakers for most patients who require cardiac pacing. Ventricular pacemakers are less expensive, but dual-chamber pacemakers are believed to be more physiologic. However, it is not known whether either type of pacemaker results in superior clinical outcomes. METHODS: The Pacemaker Selection in the Elderly study was a 30-month, single-blind, randomized, controlled comparison of ventricular pacing and dual-chamber pacing in 407 patients 65 years of age or older in 29 centers. Patients received a dual-chamber pacemaker that had been randomly programmed to either ventricular pacing or dual-chamber pacing. The primary end point was health-related quality of life as measured by the 36-item Medical Outcomes Study Short-Form General Health Survey. RESULT: The average age of the patients was 76 years (range, 65 to 96), and 60 percent were men. Quality of life improved significantly after pacemaker implantation (P<0.001), but there were no differences between the two pacing modes in either the quality of life or prespecified clinical outcomes (including cardiovascular events or death). However, 53 patients assigned to ventricular pacing (26 percent) were crossed over to dual-chamber pacing because of symptoms related to the pacemaker syndrome. Patients with sinus-node dysfunction, but not those with atrioventricular block, had moderately better quality of life and cardiovascular functional status with dual-chamber pacing than with ventricular pacing. Trends of borderline statistical significance in clinical end points favoring dual-chamber pacing were observed in patients with sinus-node dysfunction, but not in those with atrioventricular block. CONCLUSION: The implantation of a permanent pacemaker improves health-related quality of life. However, the quality-of-life benefits associated with dual-chamber pacing as compared with ventricular pacing are observed principally in the subgroup of patients with sinus-node dysfunction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199804163381602

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 28

  1. 10.1016/0002-9149(66)90004-X · doi:10.1016/0002-9149(66)90004-x
  2. 10.1111/j.1540-8159.1990.tb06883.x · DOI
  3. 10.1136/hrt.67.1.57 · DOI
  4. Dreifus LS, 1991, Circulation, 84, 455, 10.1161/01.CIR.84.1.455 · DOI · Paper page
  5. 10.1111/j.1540-8159.1987.tb06035.x · DOI
  6. 10.1161/01.CIR.64.6.1227 · DOI · Paper page
  7. 10.1016/0002-8703(88)90244-X · DOI · Paper page
  8. Diggle PJ, Liang K-Y, Zeger SL. Analysis of longitudinal data. Oxford, England: Oxford University Press, 1994.
  9. 10.2307/2281868 · doi:10.2307/2281868 · Paper page
  10. 10.1016/0002-9149(92)90229-R · DOI
  11. Lamas GA, 1992, Circulation, 86, I
  12. 10.1016/0735-1097(88)90166-0 · doi:10.1016/0735-1097(88)90166-0
  13. 10.1016/0002-9149(86)90028-7 · DOI
  14. 10.1111/j.1540-8159.1995.tb04733.x · doi:10.1111/j.1540-8159.1995.tb04733.x
  15. 10.1111/j.1540-8159.1988.tb03957.x · DOI
  16. 10.1111/j.1540-8159.1992.tb02920.x · DOI
  17. 10.1111/j.1540-8159.1994.tb01342.x · doi:10.1111/j.1540-8159.1994.tb01342.x
  18. 10.1016/S0002-9149(97)00085-4 · DOI
  19. 10.1016/0002-9149(90)90025-V · DOI
  20. 10.1016/S0140-6736(97)03425-9 · DOI · Paper page
  21. 10.1016/0735-1097(92)90616-U · DOI
  22. 10.1111/j.1540-8159.1992.tb03112.x · DOI
  23. Lamas GA, 1995, Circulation, 91, 1063, 10.1161/01.CIR.91.4.1063 · DOI
  24. 10.1111/j.0954-6820.1983.tb10639.x · DOI
  25. 10.1111/j.1540-8159.1990.tb06900.x · DOI
  26. 10.1111/j.1540-8159.1992.tb05138.x · DOI
  27. 10.1111/j.1540-8159.1996.tb04210.x · DOI
  28. 10.1016/0002-9149(88)90938-1 · DOI

Cited by

See all 631

Metadata

Authors
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., Mangione, C. M., Goldman, L., Griffin, J. J., Maloney, J. D., Rizo-Patrón, C., Venditti, F. J., & Wilkoff, B. L.
Venue
New England Journal of Medicine
Published
1998-04-16
Volume
338
Issue
16
Pages
1097-1104
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2036344680
Cited by
631
References
2
FWCI
22.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality of Life and Clinical Outcomes in Elderly Patients Treated with Ventricular Pacing as Compared with Dual-Chamber Pacing. https://app.cochat.ai/papers/10.1056/nejm199804163381602
The paper
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., Mangione, C. M., Goldman, L., Griffin, J. J., Maloney, J. D., Rizo-Patrón, C., Venditti, F. J., & Wilkoff, B. L. (1998). Quality of Life and Clinical Outcomes in Elderly Patients Treated with Ventricular Pacing as Compared with Dual-Chamber Pacing. New England Journal of Medicine. https://doi.org/10.1056/nejm199804163381602

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.