CoChat

Neural Monitoring of Vasovagal Syncope

ELLENBOGEN, KENNETH A., MORILLO, CARLOS A., WOOD, MARK A., GILLIGAN, DAVID M., ECKBERG, DWAIN L., SMITH, MICHAEL L. · 1997 · Pacing and Clinical Electrophysiology
Cited by 60

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Head‐up tilt testing has become a valuable and widely accepted diagnostic tool for evaluation of patients with vasovagal syncope. This test has afforded clinical researchers the opportunity to focus on the hemodynamic, humoral, and neural changes that accompany syncope. We review the animal and clinical studies that provide insight into the possible pathophysiological mechanisms involved in vasovagal syncope. Hemodynamic measurements in patients with vasovagal syncope suggest that a relative decrease in ventricular size and increase in cardiac contractility may be seen in many patients with vasovagal syncope. Patients with vasovagal syncope have also demonstrated numerous “exaggerated” neurohumoral responses to syncope. Differential changes in plasma levels of epinephrine, renin, endothelin, vasopressin, cortisol, prolactin, beta endorphins, and substance P have been reported by some investigators either prior to or during a syncopal episode in patients with vasovagal syncope. The precise pathophysiological significance of these measurements is unknown at the present time. Measurements of autonomic tone may be accomplished indirectly with analysis of heart rate variability or baroreflex slope, or directly by sympathetic neural recordings of the peroneal nerve. We have demonstrated decreased baroreflex slopes in patients with vasovagal syncope. Using microneurography, we and others have demonstrated decreased sympathetic nerve activity occurring 11 ± 3 seconds prior to syncope during bead‐up tilt table testing. A variety of other abnormal reflexes, including blunted forearm blood flow responses during exercise, have been demonstrated by others. These observations suggest that pacing instituted after the event may not be as helpful as the use of a hemodynamic sensor that will result in the initiation of pacing prior to sympathetic withdrawal or modify the decrease in sympathetic tone that occurs prior to syncope.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1997.tb03905.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 60

Metadata

Authors
ELLENBOGEN, K. A., MORILLO, C. A., WOOD, M. A., GILLIGAN, D. M., ECKBERG, D. L., & SMITH, M. L.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1997-03
Volume
20
Issue
3
Pages
788-794
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1966538209
Cited by
60
References
3
FWCI
3.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neural Monitoring of Vasovagal Syncope. https://app.cochat.ai/papers/10.1111/j.1540-8159.1997.tb03905.x
The paper
ELLENBOGEN, K. A., MORILLO, C. A., WOOD, M. A., GILLIGAN, D. M., ECKBERG, D. L., & SMITH, M. L. (1997). Neural Monitoring of Vasovagal Syncope. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1997.tb03905.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.