Modification of Patient Driving Behavior After Implantation of a Cardioverter Defibrillator

CONTI, JAMIE BETH, WOODARD, DAVID A., TUCKER, KELLY J., BRYANT, BETH, KING, LEANN C., CURTIS, ANNE B. · 1997 · Pacing and Clinical Electrophysiology
Cited by 45

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Driving habits among recipients of ICDs have not been well characterized previously, yet such information may have implications for development of national policy. This study was undertaken to characterize driving behavior after defibrillator implantation in our patient population. From 1988–1993, 82 ICDs were implanted at the University of Florida. All patients received defibrillator teaching preoperatively and postoperatively with particular emphasis placed on driving restrictions. A standardized questionnaire was developed to ascertain driving behavior, compliance with restrictions, and occurrence of motor vehicle accidents following implantation. The patients were divided into two groups according to whether or not they had received a shock from their device since implantation. Group I patients did, and Group II patients did not. Fifty‐two out of 82 (63%, Group I) patients had at least one shock. The remaining 30 patients had received no shocks. Mean age and gender were no different between the two groups. Mean time since implantation was 6 ± 1.3 years in Group I, compared to 4 ± 1.5 years In Group II (P = 0.001). Forty‐seven out of 52 (90%) and 26 out of 30 (87%) in Groups I and II, respectively, resumed driving after defibrillator implantation. There was no difference in the amount of time that passed prior to resumption of driving. Group I patients drove more, 20.5 ± 27 miles/day compared to patients in Group II, 8.3 ± 9.7 miles/day (P = 0.02). No patient experienced device discharge during driving; likewise, no patient was involved in a motor vehicle accident secondary to their device firing. Sixty‐seven out of 82 (82%) patients complied with the instructions they thought they heard; seven patients in Group I and eight patients in Group II deliberately did not follow our advice. The majority of patients do comply with physician instructions, although the instructions they remember are not always the instructions given. If a national policy is created to prohibit driving after ICD implantation, effective enforcement may be difficult.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1997.tb04237.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 45

Metadata

Authors
CONTI, J. B., WOODARD, D. A., TUCKER, K. J., BRYANT, B., KING, L. C., & CURTIS, A. B.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1997-09
Volume
20
Issue
9
Pages
2200-2204
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1975167270
Cited by
45
References
2
FWCI
2.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modification of Patient Driving Behavior After Implantation of a Cardioverter Defibrillator. https://app.cochat.ai/papers/10.1111/j.1540-8159.1997.tb04237.x
The paper
CONTI, J. B., WOODARD, D. A., TUCKER, K. J., BRYANT, B., KING, L. C., & CURTIS, A. B. (1997). Modification of Patient Driving Behavior After Implantation of a Cardioverter Defibrillator. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1997.tb04237.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.