Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 343

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Permanent Left Ventricular Pacing With Transvenous Leads Inserted Into The Coronary Veins

DAUBERT, J. CLAUDE, RITTER, PHILIPPE, LE BRETON, HERVÉ, GRAS, DANIEL, LECLERCQ, CHRISTOPHE, LAZARUS, ARNAUD, MUGICA, JACQUES, MABO, PHILIPPE, CAZEAU, SERGE · 1998 · Pacing and Clinical Electrophysiology

Abstract

This paper describes a preliminary experiment ‐ conducted jointly by 2 centers ‐ of permanent left ventricular pacing using leads inserted by the transvenous route and through the coronary sinus into the cardiac veins of the left ventricle free wall. The aim was to obtain permanent biventricular pacing in a totally endocavitary configuration in pattents with severe LV dysfunction and drug‐refractory heart failure. Two types of leads were used: nonspecific unipolar leads at the beginning of the experiment, followed by leads specifically designed to be used in the coronary sinus in a second step. The electrode could be fitted in an adequate location in 35 of the 47 patients (75.4%), with a 1.15±0.7 V acute pactng threshold and 11.8±5.7 mV R wave amplitude. The success rate was significantly higher with the specific electrodes (81.8% vs 53,3%, p < 0.001). The pacing and sensing thresholds upon implantation were not influenced by the type of lead or by the localization of the cardiac vein that was catheterized (great cardiac vein, lateral vein, postero‐lateral or posterior vein, mid cardiac vein). In contrast, the pacing threshold was significantly lower (0.8 ± 0.2 vs L8 ± 0.8 V; p = 0.002) and the R wave amplitude tended to be greater (13.1 ± 4.5 mV vs 9.3 ± 6.5 mV; p = 0.07) when the tip electrode could be inserted distally into the vein, by comparison with a proximal site near the ostium. At the end of follow‐up (10.2 ± 8.7 months), 34 out of the 35 leads were still fully functional, with a chronic pacing threshold of 1.8 ± 0.7 V and a R wave amplitude of 10.7 ± 6 mV. To conclude, permanent LV pacing via the transvenous route is possible in most patients, with excellent safety and long‐term results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1998.tb01096.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 343

Metadata

Authors
DAUBERT, J. C., RITTER, P., LE BRETON, H., GRAS, D., LECLERCQ, C., LAZARUS, A., MUGICA, J., MABO, P., & CAZEAU, S.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1998-01
Volume
21
Issue
1
Pages
239-245
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2074831861
Cited by
343
References
3
FWCI
16.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Permanent Left Ventricular Pacing With Transvenous Leads Inserted Into The Coronary Veins. https://app.cochat.ai/papers/10.1111/j.1540-8159.1998.tb01096.x
The paper
DAUBERT, J. C., RITTER, P., LE BRETON, H., GRAS, D., LECLERCQ, C., LAZARUS, A., MUGICA, J., MABO, P., & CAZEAU, S. (1998). Permanent Left Ventricular Pacing With Transvenous Leads Inserted Into The Coronary Veins. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1998.tb01096.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.