Permanent Left Ventricular Pacing With Transvenous Leads Inserted Into The Coronary Veins
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper describes a preliminary experiment ‐ conducted jointly by 2 centers ‐ of permanent left ventricular pacing using leads inserted by the transvenous route and through the coronary sinus into the cardiac veins of the left ventricle free wall. The aim was to obtain permanent biventricular pacing in a totally endocavitary configuration in pattents with severe LV dysfunction and drug‐refractory heart failure. Two types of leads were used: nonspecific unipolar leads at the beginning of the experiment, followed by leads specifically designed to be used in the coronary sinus in a second step. The electrode could be fitted in an adequate location in 35 of the 47 patients (75.4%), with a 1.15±0.7 V acute pactng threshold and 11.8±5.7 mV R wave amplitude. The success rate was significantly higher with the specific electrodes (81.8% vs 53,3%, p < 0.001). The pacing and sensing thresholds upon implantation were not influenced by the type of lead or by the localization of the cardiac vein that was catheterized (great cardiac vein, lateral vein, postero‐lateral or posterior vein, mid cardiac vein). In contrast, the pacing threshold was significantly lower (0.8 ± 0.2 vs L8 ± 0.8 V; p = 0.002) and the R wave amplitude tended to be greater (13.1 ± 4.5 mV vs 9.3 ± 6.5 mV; p = 0.07) when the tip electrode could be inserted distally into the vein, by comparison with a proximal site near the ostium. At the end of follow‐up (10.2 ± 8.7 months), 34 out of the 35 leads were still fully functional, with a chronic pacing threshold of 1.8 ± 0.7 V and a R wave amplitude of 10.7 ± 6 mV. To conclude, permanent LV pacing via the transvenous route is possible in most patients, with excellent safety and long‐term results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multisite Pacing for End‐Stage Heart Failure: Early Experience
CAZEAU, S., RITTER, P., LAZARUS, A., GRAS, D., BACKDACH, H., MUNDLER, O., & MUGICA, J. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03218.x · Cited by 443
Self-citationSuccessful Long‐Term Ventricular Pacing Via the Coronary Sinus After the Fontan Operation
Rosenthal, É., Qureshi, S. A., & Crick, J. C. P. (1995) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1995.tb03874.x · Cited by 29
Ventricular pacing from the coronary sinus of a patient with a Fontan circulation.
Blackburn, M. E., & Gibbs, J. L. (1993) · Heart · doi:10.1136/hrt.70.6.578 · Cited by 27
Cited by
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C., Garrigue, S., Kappenberger, L., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,751
Self-citationYu, C.-M., Chau, E., Sanderson, J. E., Fan, K., Tang, M.-O., Fung, W.-H., Lin, H., Kong, S.-L., Lam, Y.-M., Hill, M. R. S., et al. (2002) · Circulation · doi:10.1161/hc0402.102623 · Cited by 1,110
Yu, C.-M., Bleeker, G. B., Fung, J. W.-H., Schalij, M. J., Zhang, Q., van der Wall, E. E., Chan, Y.-S., Kong, S.-L., & Bax, J. J. (2005) · Circulation · doi:10.1161/circulationaha.105.538272 · Cited by 705
Yu, C.-M., Fung, W.-H., Lin, H., Zhang, Q., Sanderson, J. E., & Lau, C.-P. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03404-5 · Cited by 649
McAlister, F. A., Ezekowitz, J., Hooton, N., Vandermeer, B., Spooner, C., Dryden, D. M., Page, R. L., Hlatky, M. A., & Rowe, B. H. (2007) · JAMA · doi:10.1001/jama.297.22.2502 · Cited by 569
Retiming the failing heart: principles and current clinical status of cardiac resynchronization
Leclercq, C., & Kass, D. A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01747-8 · Cited by 495
Self-citationAnsalone, G., Giannantoni, P., Ricci, R., Trambaiolo, P., Fedele, F., & Santini, M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01772-7 · Cited by 481
Leclercq, C. (2002) · European Heart Journal · doi:10.1053/euhj.2002.3232 · Cited by 452
Self-citationPenicka, M., Bartunek, J., De Bruyne, B., Vanderheyden, M., Goethals, M., De Zutter, M., Brugada, P., & Geelen, P. (2004) · Circulation · doi:10.1161/01.cir.0000116765.43251.d7 · Cited by 405
GRAS, D., MABO, P., TANG, T., LUTTIKUIS, O., CHATOOR, R., PEDERSEN, A., TSCHELIESSNIGG, H., DEHARO, J., PUGLISI, A., SILVESTRE, J., et al. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01162.x · Cited by 398
Self-citationAlonso, C., Leclercq, C., Victor, F., Mansour, H., de Place, C., Pavin, D., Carré, F., Mabo, P., & Daubert, J. C. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00588-3 · Cited by 269
Self-citationLecoq, G., Leclercq, C., Leray, E., Crocq, C., Alonso, C., Place, C. D., Mabo, P., & Daubert, C. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi146 · Cited by 246
Self-citationThe Deleterious Consequences of Right Ventricular Apical Pacing: Time to Seek Alternate Site Pacing
MANOLIS, A. S. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00338.x · Cited by 183
Notabartolo, D., Merlino, J. D., Smith, A. L., DeLurgio, D. B., Vera, F. V., Easley, K. A., Martin, R. P., & León, A. R. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.05.072 · Cited by 180
Garrigue, S., Jaïs, P., Espil, G., Labeque, J.-N., Hocini, M., Shah, D. C., Haïssaguerre, M., & Clementy, J. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01892-6 · Cited by 177
Gras, D., Böcker, D., Lunati, M., Wellens, H. J. J., Calvert, M., Freemantle, N., Gervais, R., Kappenberger, L., Tavazzi, L., Erdmann, E., et al. (2007) · EP Europace · doi:10.1093/europace/eum080 · Cited by 172
“Standard leads were used to stimulate the RA and RV, and an AttainTM (Medtronic) cardiac vein lead, specifically designed for stimulation inside a CS tributary, was used to stimulate the LV epicardial surface, using the method described originally by Daubert et al.(12) No precise recommendation was made with regard to…”
MethodSelf-citation20 Years of Cardiac Resynchronization Therapy
Leyva, F., Nisam, S., & Auricchio, A. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.06.1178 · Cited by 169
Myocardial Gene Expression in Heart Failure Patients Treated With Cardiac Resynchronization Therapy
Vanderheyden, M., Mullens, W., Delrue, L., Goethals, M., de Bruyne, B., Wijns, W., Geelen, P., Verstreken, S., Wellens, F., & Bartunek, J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.087 · Cited by 168
Metadata
- Authors
- DAUBERT, J. C., RITTER, P., LE BRETON, H., GRAS, D., LECLERCQ, C., LAZARUS, A., MUGICA, J., MABO, P., & CAZEAU, S.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1998-01
- Volume
- 21
- Issue
- 1
- Pages
- 239-245
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2074831861
- Cited by
- 343
- References
- 3
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.