Direct His‐Bundle Pacing: Present and Future

DESHMUKH, PRAMOD M., ROMANYSHYN, MARY · 2004 · Pacing and Clinical Electrophysiology

Abstract

Direct His‐bundle pacing (DHBP) produces rapid sequential multisite synchronous ventricular activation and, therefore, would be an ideal alternative to right ventricular apical (RVA) pacing. In 54 patients with cardiomyopathy, ejection fraction (EF) 0.23 ± 0.11, persistent atrial fibrillation, and normal QRS < 120 ms. DHBP was attempted. This was successful in 39 patients. In seven patients, the effect of increasing heart rate on contractility (Treppe effect) was investigated. Twelve patients who also received a RVA lead underwent cardiopulmonary testing. After a mean follow‐up of 42 months, 29 patients are still alive with EF improving from 0.23 ± 0.11 to 0.33 ± 0.15. Functional class improved from 3.5 to 2.2. DP/dt increased at each pacing site (P < 0.05) as the heart rate increased to 60, 100, and 120 beats/min. Rise in dP/dt by DHBP pacing at 120 beats/min was at least 170 ± mmHg/s, greater than any other site in the ventricle (P < 0.05). Cardiopulmonary testing revealed longer exercise time (RVA 255 ± 110 s) (His 280 ± 104 s) (P < 0.05), higher O 2 uptake (RVA 15 ± 4 mL/kg per minute) (His 16 ± 4 mL/kg minute) (P < 0.05), and later anaerobic threshold (RVA 126 ± 71 s) (His 145 ± 74 s) (P < 0.05) with DHBP compared to RVA pacing. Long‐term DHBP is safe and effective in humans. DHBP is associated with a superior Treppe effect and increased cardiopulmonary reserve when compared to RVA pacing. (PACE 2004; 27[Pt. II]:862–870)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2004.00548.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
DESHMUKH, P. M., & ROMANYSHYN, M.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2004-05-25
Volume
27
Issue
6p2
Pages
862-870
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1754981012
Cited by
183
References
2
FWCI
7.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct His‐Bundle Pacing: Present and Future. https://app.cochat.ai/papers/10.1111/j.1540-8159.2004.00548.x
The paper
DESHMUKH, P. M., & ROMANYSHYN, M. (2004). Direct His‐Bundle Pacing: Present and Future. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2004.00548.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.