Accuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies

PURERFELLNER, HELMUT, GILLIS, ANNE M., HOLBROOK, REECE, HETTRICK, DOUGLAS A.·2004·Pacing and Clinical Electrophysiology

Abstract

The clinical application of atrial tachyarrhythmia (AT) episode data stored by implantable devices is presently limited by the high proportion of inappropriate detection. We quantified the percentage of inappropriate AT detection in two implantable devices with AT diagnostics and therapies via meta‐analysis of stored AT episodes from a number of clinical trials. The AT500 and GEM III AT, contain dual chamber logic to discriminate AT from ventricular tachycardia and far‐field R wave (FFRW) oversensing using dual chamber bipolar electrograms. A subset of data from four clinical trials of 1,142 patients was considered. Manual analysis was performed on 21,553 stored episodes with atrial EGM and marker channel from 409 patients with stored episodes and the market‐released device detection configuration. The percentage of episodes with inappropriate detection and termination was evaluated and compared between septal and nonseptal lead locations. The percentage of inappropriately detected episodes receiving ATP therapy was also determined. The percentage of episodes appropriately detected and the percentage of net episode duration (i.e., burden) recorded by the device were also determined from a separate analysis of 24‐hour Holter recordings from a subset of 40 patients from one trial. Adjusted estimates of the percentage of inappropriate detection were 95.3% (93.5–96.7; 95% CI) for AT500 and 95.7% (84.3–98.9) for GEM III AT. Inappropriate detection was primarily due to FFRW oversensing or brief runs of premature atrial contractions (PACs). The device detected 100% of the sustained atrial arrhythmia episodes and 95.3% (range 76.1–99.9) of the net AT duration observed on the Holter recordings. AT detection was not influenced by atrial lead location. Appropriate detection of normal sinus rhythm at episode termination was 83.7% (80.7–86.3) for AT500 and 92.1% (84.5–96.2) for GEM III AT. Accurate detection and discrimination of FFRWs validates the reliability of AT diagnostic data and decreases the risk of inappropriate device therapy. (PACE 2004; 27:983–992)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2004.00569.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
PURERFELLNER, H., GILLIS, A. M., HOLBROOK, R., & HETTRICK, D. A.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2004-07
Volume
27
Issue
7
Pages
983-992
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2050520822
Cited by
162
References
1
FWCI
4.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies. https://app.cochat.ai/papers/10.1111/j.1540-8159.2004.00569.x
The paper
PURERFELLNER, H., GILLIS, A. M., HOLBROOK, R., & HETTRICK, D. A. (2004). Accuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2004.00569.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.