Accuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The clinical application of atrial tachyarrhythmia (AT) episode data stored by implantable devices is presently limited by the high proportion of inappropriate detection. We quantified the percentage of inappropriate AT detection in two implantable devices with AT diagnostics and therapies via meta‐analysis of stored AT episodes from a number of clinical trials. The AT500 and GEM III AT, contain dual chamber logic to discriminate AT from ventricular tachycardia and far‐field R wave (FFRW) oversensing using dual chamber bipolar electrograms. A subset of data from four clinical trials of 1,142 patients was considered. Manual analysis was performed on 21,553 stored episodes with atrial EGM and marker channel from 409 patients with stored episodes and the market‐released device detection configuration. The percentage of episodes with inappropriate detection and termination was evaluated and compared between septal and nonseptal lead locations. The percentage of inappropriately detected episodes receiving ATP therapy was also determined. The percentage of episodes appropriately detected and the percentage of net episode duration (i.e., burden) recorded by the device were also determined from a separate analysis of 24‐hour Holter recordings from a subset of 40 patients from one trial. Adjusted estimates of the percentage of inappropriate detection were 95.3% (93.5–96.7; 95% CI) for AT500 and 95.7% (84.3–98.9) for GEM III AT. Inappropriate detection was primarily due to FFRW oversensing or brief runs of premature atrial contractions (PACs). The device detected 100% of the sustained atrial arrhythmia episodes and 95.3% (range 76.1–99.9) of the net AT duration observed on the Holter recordings. AT detection was not influenced by atrial lead location. Appropriate detection of normal sinus rhythm at episode termination was 83.7% (80.7–86.3) for AT500 and 92.1% (84.5–96.2) for GEM III AT. Accurate detection and discrimination of FFRWs validates the reliability of AT diagnostic data and decreases the risk of inappropriate device therapy. (PACE 2004; 27:983–992)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Antithrombotic Therapy for Atrial Fibrillation
Lip, G. Y. H., Banerjee, A., Boriani, G., Chiang, C. E., Fargo, R., Freedman, B., Lane, D. A., Ruff, C. T., Turakhia, M., Werring, D., et al. (2018) · Chest · doi:10.1016/j.chest.2018.07.040 · Cited by 939
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526
“The accuracy of atrial arrhythmia detection has been established (13,14).”
BackgroundMinimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node Disease
Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D., Sheldon, T., & Lamas, G. A. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071880 · Cited by 520
Self-citationBoriani, G., Glotzer, T. V., Santini, M., West, T. M., De Melis, M., Sepsi, M., Gasparini, M., Lewalter, T., Camm, J. A., & Singer, D. E. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht491 · Cited by 427
Whellan, D. J., Ousdigian, K. T., Al-Khatib, S. M., Pu, W., Sarkar, S., Porter, C. B., Pavri, B. B., & O'Connor, C. M. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.089 · Cited by 374
Martin, D. T., Bersohn, M. M., Waldo, A. L., Wathen, M. S., Choucair, W. K., Lip, G. Y. H., Ip, J., Holcomb, R., Akar, J. G., & Halperin, J. L. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv115 · Cited by 364
Daoud, E. G., Glotzer, T. V., Wyse, D. G., Ezekowitz, M. D., Hilker, C., Koehler, J., & Ziegler, P. D. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.022 · Cited by 326
“No significant differnces in AT/AF burden was seen in these 26 patients comared to the 20 who had prior AT/AF using the 5-minute hreshold for detection of AT/AF.”
MethodInfluentialStroke Risk as a Function of Atrial Fibrillation Duration and CHA 2 DS 2 -VASc Score
Kaplan, R. M., Koehler, J., Ziegler, P. D., Sarkar, S., Zweibel, S., & Passman, R. S. (2019) · Circulation · doi:10.1161/circulationaha.119.041303 · Cited by 284
Comparison of continuous versus intermittent monitoring of atrial arrhythmias
Ziegler, P. D., Koehler, J. L., & Mehra, R. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.030 · Cited by 282
Mahajan, R., Perera, T., Elliott, A. D., Twomey, D. J., Kumar, S., Munwar, D. A., Khokhar, K. B., Thiyagarajah, A., Middeldorp, M. E., Nalliah, C. J., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx731 · Cited by 275
Charitos, E. I., Stierle, U., Ziegler, P. D., Baldewig, M., Robinson, D. R., Sievers, H.-H., & Hanke, T. (2012) · Circulation · doi:10.1161/circulationaha.112.098079 · Cited by 196
Turakhia, M. P., Ziegler, P. D., Schmitt, S. K., Chang, Y., Fan, J., Than, C. T., Keung, E. K., & Singer, D. E. (2015) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.114.003057 · Cited by 197
Clinical Classifications of Atrial Fibrillation Poorly Reflect Its Temporal Persistence
Charitos, E. I., Pürerfellner, H., Glotzer, T. V., & Ziegler, P. D. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.019 · Cited by 188
Self-citationShanmugam, N., Boerdlein, A., Proff, J., Ong, P., Valencia, O., Maier, S. K. G., Bauer, W. R., Paul, V., & Sack, S. (2012) · Europace · doi:10.1093/europace/eur293 · Cited by 182
“95% sensitivity and specificity for the detection of atrial tachycardia/atrial fibrillation (AT/AF) episodes and measurements of AT/AF burden.(6) Patients were included in the analysis if the total detected AHRE burden in a 24 h period exceeded an accumulative total of 14 min.”
BackgroundZiegler, P. D., Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Koehler, J. L., & Hilker, C. E. (2010) · Stroke · doi:10.1161/strokeaha.109.571455 · Cited by 173
“常发作负荷的敏感性和特异性均 >95%([13])。 NDAF 定义为在研究的任意 1 天内通过设备发 现的持续至少 5 分钟的房性心律失常。本次分析中, 只有持续至少 5 分钟的 AF 或 AT 被承认,这样可以 很大程度地避免将房性过度感知误认为 AF 发作 ([14])。”
Understanding atrial symptom reports: objective versus subjective predictors
SEARS, S. F., SERBER, E. R., ALVAREZ, L. G., SCHWARTZMAN, D. S., HOYT, R. H., & UJHELYI, M. R. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00171.x · Cited by 70
Clinical significance of atrial fibrillation detected by cardiac implantable electronic devices
DeCicco, A. E., Finkel, J. B., Greenspon, A. J., & Frisch, D. R. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.01.001 · Cited by 38
Metadata
- Authors
- PURERFELLNER, H., GILLIS, A. M., HOLBROOK, R., & HETTRICK, D. A.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2004-07
- Volume
- 27
- Issue
- 7
- Pages
- 983-992
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2050520822
- Cited by
- 162
- References
- 1
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.