A Comparative Study of the Action of Dexamethasone Sodium Phosphate and Dexamethasone Acetate in Steroid‐Eluting Pacemaker Leads

SINGARAYAR, SURESH, KISTLER, PETER M., DE WINTER, CHANTAL, MOND, HARRY · 2005 · Pacing and Clinical Electrophysiology
Cited by 21

The DOI matches its Crossref record.

Abstract

Background: The aim of this study was to characterize acute and medium‐term pacemaker lead performance with the two most commonly used glucocorticosteroids: dexamethasone sodium phosphate and dexamethasone acetate. Methods: Forty sets of atrial and ventricular passive‐fixation leads containing either dexamethasone sodium phosphate or dexamethasone acetate were implanted as dual chamber pacemakers. Randomization was equally distributed to both arms of the study. Stimulation thresholds, lead impedance, and sensing were measured on the day of implant, day 1, 1 month, 3 months, and 6 months following the implant. Results: For the dexamethasone sodium phosphate arm, the atrial stimulation thresholds were 0.9 ± 0.1 V at implant and 0.8 ± 0.1 V at 6 months, and in the ventricle 0.5 ± 0.1 V at implant and 0.6 ± 0.1 V at 6 months. In the dexamethasone acetate arm, the atrial stimulation thresholds were 0.7 ± 0.1 V at implant and at 6 months, and in the ventricle 0.5 ± 0.1 V at implant and at 6 months. There were no significant differences between dexamethasone sodium phosphate or dexamethasone acetate leads for stimulation thresholds at any of the intervals of follow‐up. P‐ and R‐wave sensing were similarly maintained over the duration of follow‐up with no significant differences between groups at any of the intervals of follow‐up. Pacing lead impedance showed a trend towards lower values in the dexamethasone acetate arm, which only reached statistical significance at 3 months and beyond for ventricular leads. Conclusions: Leads containing dexamethasone sodium phosphate and dexamethasone acetate demonstrate equivalent and excellent acute and medium‐term pacemaker lead performance characteristics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2005.40055.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 21

Metadata

Authors
SINGARAYAR, S., KISTLER, P. M., DE WINTER, C., & MOND, H.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2005-04
Volume
28
Issue
4
Pages
311-315
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2151259334
Cited by
21
References
0
FWCI
0.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparative Study of the Action of Dexamethasone Sodium Phosphate and Dexamethasone Acetate in Steroid‐Eluting Pacemaker Leads. https://app.cochat.ai/papers/10.1111/j.1540-8159.2005.40055.x
The paper
SINGARAYAR, S., KISTLER, P. M., DE WINTER, C., & MOND, H. (2005). A Comparative Study of the Action of Dexamethasone Sodium Phosphate and Dexamethasone Acetate in Steroid‐Eluting Pacemaker Leads. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2005.40055.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.