The electrode-tissue interface: the revolutionary role of steroid-elution

MOND, HARRY G., HELLAND, JOHN R., STOKES, KENNETH, BORNZIN, GENE A., McVENES, RICK·2014·Pacing and Clinical Electrophysiology

Abstract

The electrode‐tissue interface is that area lying between the cathode of a low‐voltage implantable pacemaker or cardioverter‐defibrillator (ICD) lead and the endocardium or epi‐myocardium of the cardiac chamber being paced. The electrical stimulus that is delivered to this interface is responsible for myocyte depolarization with consequent cardiac contraction. The process by which this occurs is reasonably well understood and any explanation requires a basic understanding of the physics and cellular electrophysiology of pacing. The effective and efficient delivery of electrical energy to the myocardium via the lead is dependent on many factors to be discussed in this review. However, despite numerous evolutionary changes occurring in the cathode's material, design, and surface configuration, it was not until the incorporation of steroid‐elution to the electrode‐tissue interface that reliable and significantly low stimulation threshold cardiac pacing became possible.

Integrity signals

Registry

Crossref · 10.1111/pace.12461

Cites

69 of 69 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Dexamethasone has found great success in pacemaker stimulator implants used in the clinic, where it is incorporated into the material surrounding the electrodes and elutes over time to hamper FBR and improve implant life-time and stability.

    “Dexamethasone—a commonly used anti-inflammatory corticosteroid drug—has found great success in pacemaker stimulator implants used in the clinic, where it is incorporated into the material surrounding the electrodes and elutes over time into the surrounding tissue to hamper FBR and improve implant life-time and stability (Mond et al., 2014).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
MOND, H. G., HELLAND, J. R., STOKES, K., BORNZIN, G. A., & McVENES, R.
Affiliations
  • The Royal Melbourne Hospital (AU)
  • St. Jude Medical Implantable Electronic Systems Division (IESD) Sylmar California
  • (retired) Brainerd Minnesota
  • Medtronic (United States) (US)
Corresponding author
MOND, HARRY G.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2014-07-29
Volume
37
Issue
9
Pages
1232-1249
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W3024398725
Cited by
58
References
69
Citations by year
2026: 6 · 2025: 3 · 2024: 7 · 2023: 2 · 2022: 8 · 2021: 5 · 2020: 5 · 2019: 4 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 4 · 2014: 1
FWCI
0.75
Type
journal article
Language
en
Open access
closed
Locations
Pacing and Clinical Electrophysiology (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Surgery › Coronary Interventions and Diagnostics
Keywords
electrode-tissue interface, steroid-eluting leads, cardiac pacing, implantable cardioverter-defibrillator leads, pacemaker leads, cardiac depolarization, cardiac electrophysiology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review