Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 18Cardiovascular Syncope and Autonomic DisordersHeart Rate Variability and Autonomic ControlTakotsubo Cardiomyopathy and Associated Phenomena

The DOI matches its Crossref record.

Myocardial contractility and cardiac filling measured by impedance cardiography in patients with nitroglycerine-induced vasovagal syncope

MITRO, PETER, HIJOVÁ, EMÍLIA·2006·Pacing and Clinical Electrophysiology

Abstract

Objective: Increased myocardial contractility and inadequate cardiac filling leading to activation of the Bezold‐Jarisch reflex were proposed as possible triggering mechanisms of vasovagal syncope (VVS). In the present study noninvasive hemodynamic measurements were performed in order to examine the role of myocardial contractility and cardiac filling in pathogenesis of VVS. Methods: Hemodynamic parameters were measured during head‐up tilt test (HUT) by impedance cardiography in 46 patients with unexplained syncope. Myocardial contractility was measured as index of contractility (IC), acceleration index (ACI), and ejection fraction (EF). Afterload was measured as systemic vascular resistance index (SVRI) and preload was expressed as end‐diastolic index (EDI). Serial measurements were done 1 minute before HUT, during HUT at 1‐minute intervals, and 1 minute after completion of HUT. Results: HUT was positive in 30 patients (10 men, 20 women, mean age 36 ± 16 years) and negative in 16 patients (8 men, 8 women, mean age 31 ± 14 years). No significant differences were observed between HUT(+) and HUT(−) groups in hemodynamic parameters at supine rest and during HUT until the development of syncope. SVRI was lower in HUT(+) than in HUT(−) group at syncope (122.7 + 66.3 vs 185.6 + 51.4 dyn sec cm−5/m 2, P = 0.002) and after syncope (117.0 + 61.1 vs 198.0 + 95.7 dyn sec cm−5/m 2, P = 0.007). ACI, IC, EF, and EDI did not differ between groups at syncope. After syncope EF was higher in HUT(+) group compared to HUT(−) group (59.2 + 6.1 vs 52.7 + 9.4%, P = 0.02). Conclusion: The role of increased myocardial contractility and decreased cardiac filling is not confirmed in the present study.

Overview

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2006.00299.x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 31

  1. 10.1016/0165-1838(82)90001-7 · DOI
  2. 10.1111/j.1748-1716.1972.tb05247.x · DOI
  3. Somers VK, 1996, Neurocardiogenic syncope, Adv Intern Med, 41, 399
  4. Watenpaugh DE, 1995, Calf venous compliance measured with head‐up tilt equals supine calf compliance, J Gravit Physiol, 2, P21
  5. 10.1002/clc.4960190212 · DOI
  6. 10.1046/j.1540-8167.2001.00791.x · DOI
  7. 10.1161/01.CIR.101.7.777 · DOI
  8. 10.1111/j.1553-2712.2003.tb00054.x · DOI
  9. 10.1097/00003465-200019030-00001 · DOI
  10. 10.1136/hrt.79.5.437 · DOI
  11. 10.1097/00005373-199131080-00011 · DOI
  12. 10.1378/chest.114.6.1643 · DOI
  13. Hartleb M, 2000, Usefulness of thoracic electrical bioimpedance in detection of ejection fraction changes, J Physiol Pharmacol, 51, 151
  14. 10.1046/j.1460-9592.2003.t01-1-00222.x · DOI · Paper page
  15. 10.1016/j.jacc.2004.04.038 · DOI · Paper page
  16. 10.1111/j.1532-5415.1991.tb03619.x · DOI
  17. 10.1016/S0002-9149(9X)00084-9 · DOI
  18. 10.1042/cs0740347 · DOI
  19. 10.1053/eupc.2002.0271 · DOI
  20. 10.1016/S1566-0702(01)00323-X · DOI
  21. 10.1016/S0735-1097(98)00567-1 · DOI
  22. 10.1111/j.1540-8159.1999.tb00503.x · DOI
  23. 10.1016/S0735-1097(00)00567-2 · DOI
  24. Bellard E, 2003, Changes in the transthoracic impedance signal predict the outcome of a 70 degrees head‐up tilt test, Clin Sci (Lond), 104, 119, 10.1042/cs1040119 · DOI
  25. 10.1016/0165-1838(96)00040-9 · DOI
  26. 10.1016/S0735-1097(99)00500-8 · DOI
  27. 10.1067/mhj.2000.104760 · DOI
  28. 10.1046/j.1540-8167.2001.00639.x · DOI
  29. 10.1111/j.1540-8159.1997.tb03907.x · DOI
  30. 10.1046/j.1460-9592.2003.00068.x · DOI
  31. 10.1161/01.CIR.98.17.1756 · DOI

Cited by

See all 18

Metadata

Authors
MITRO, P., & HIJOVÁ, E.
Affiliations
University of Pavol Jozef Šafárik (SK)
Corresponding author
MITRO, PETER
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2006-01
Volume
29
Issue
1
Pages
1-8
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2153350462
Cited by
18
References
0
Citations by year
2019: 2 · 2015: 1 · 2014: 2 · 2013: 1
FWCI
1.81
Type
journal article
Language
en
Open access
closed
Locations
  • Pacing and Clinical Electrophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Takotsubo Cardiomyopathy and Associated Phenomena
Keywords
vasovagal syncope, cardiac contractility, cardiac filling, Bezold-Jarisch reflex, head-up tilt, systemic vascular resistance index, ejection fraction, acceleration index, nitroglycerin, unexplained syncope
MeSH terms
Adult, Analysis of Variance, Cardiac Output, Cardiography, Impedance, Electrocardiography, Female, Nitroglycerin, Humans, Male, Myocardial Contraction, Recurrence, Tilt-Table Test, Statistics, Nonparametric, Syncope, Vasovagal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Myocardial contractility and cardiac filling measured by impedance cardiography in patients with nitroglycerine-induced vasovagal syncope. https://app.cochat.ai/papers/10.1111/j.1540-8159.2006.00299.x
The paper
MITRO, P., & HIJOVÁ, E. (2006). Myocardial contractility and cardiac filling measured by impedance cardiography in patients with nitroglycerine-induced vasovagal syncope. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2006.00299.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.