Multi‐Center Clinical Experience with a Lumenless, Catheter‐Delivered, Bipolar, Permanent Pacemaker Lead: Implant Safety and Electrical Performance
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: Reduced lead diameter and reliability can be designed into transvenous permanent pacing leads through use of redundant insulation and removal of the stylet lumen. The model 3830 lead (Medtronic Inc., Minneapolis, MN, USA) is a bipolar, fixed‐screw, steroid‐eluting, lumenless, 4.1‐Fr pacing lead. Implantation can be performed in a variety of right heart sites using a deflectable catheter (Model 10600, Medtronic). Lead performance and safety were studied. Methods: Two prospective trials of 338 implanted subjects from 56 global sites were conducted. Electrical and safety data were obtained at implant, pre‐discharge, and up to 18 months post‐implant. Leads were implanted at traditional and alternate right heart sites. Results: The study enrolled 338 subjects (204 males, 70.6 ± 11.6 years) followed‐up for a mean of 10.2 months (range, 0–21.6). Mean P‐wave amplitudes ranged from 3.2 mV at 3 months to 2.9 mV at 18 months, while mean atrial pulse width thresholds at 2.5 V ranged from 0.07 ms at 3 months to 0.09 ms at 18 months. Mean R‐wave amplitudes ranged from 11.3 mV to 11.1 mV and mean ventricular pulse width thresholds at 2.5 V ranged from 0.10 ms to 0.14 ms. There were 22 ventricular and 12 atrial lead complications within 3 months post‐implant. Survival from lead‐related complications improved to a clinically acceptable rate in the cohort of patients when revised implant techniques were employed. Conclusions: With the use of recommended implant techniques, the study results support the electrical efficacy and safety of a catheter‐delivered, lumenless lead in traditional or alternate right atrium or right ventricle sites through 18 months post‐implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
The DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
Cited by
Vijayaraman, P., Chung, M. K., Dandamudi, G., Upadhyay, G. A., Krishnan, K., Crossley, G., Bova Campbell, K., Lee, B. K., Refaat, M. M., Saksena, S., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.017 · Cited by 350
Self-citationPermanent Leadless Cardiac Pacing: Results of the LEADLESS Trial
Reddy, V. Y., Knops, R. E., Sperzel, J., Miller, M. A., Petru, J., Simon, J., Sediva, L., de Groot, J. R., Tjong, F. V. Y., Jacobson, P., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.006987 · Cited by 308
The electrode-tissue interface: the revolutionary role of steroid-elution
MOND, H. G., HELLAND, J. R., STOKES, K., BORNZIN, G. A., & McVENES, R. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12461 · Cited by 58
Kristiansen, H. M., Hovstad, T., Vollan, G., & Faerestrand, S. (2012) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30458-2 · Cited by 5
Metadata
- Authors
- GAMMAGE, M. D., LIEBERMAN, R. A., YEE, R., MANOLIS, A. S., COMPTON, S. J., KHAZEN, C., SCHAAF, K., OLESON, K. A., CROSSLEY, G. H., & for the Worldwide SelectSecure Clinical Investigators
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2006-08
- Volume
- 29
- Issue
- 8
- Pages
- 858-865
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2007126234
- Cited by
- 86
- References
- 3
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.