CoChat

Psychological Reaction to Potential Malfunctioning of Implantable Defibrillators

Open access
VAN DEN BROEK, KRISTA C., DENOLLET, JOHAN, NYKLÍČEK, IVAN, VAN DER VOORT, PEPIJN H. · 2006 · Pacing and Clinical Electrophysiology
Cited by 36

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background: Psychological problems following implantable cardioverter defibrillators (ICD) implantation are diverse and include increased levels of anxiety. Anxiety may even rise further when possible malfunctioning of an ICD is announced, with a higher risk of serious ventricular arrhythmias and death as a consequence. Following the public statement of Medtronic, all patients in the Netherlands with the specific Medtronic ICD were contacted for extra device evaluation. The aim of this exploratory study was to determine whether the proportion of ICD patients with high levels of anxiety would increase after this extra device evaluation. Methods: Patients were recruited from an ongoing prospective study on psychological effects of ICD implantation. Thirty‐three patients completed the State subscale of the State‐Trait Anxiety Inventory (STAI) before and after extra device evaluation. The STAI can identify patients with high levels of anxiety. Results: A high level of anxiety was experienced by two patients (6.1%) at baseline and eight patients (24.2%) at follow‐up (P = 0.031). Hence, ICD patients were significantly more likely to experience high levels of anxiety following the public statement of potential malfunctioning of their device. Conclusion: A public statement regarding device safety may increase levels of anxiety among ICD patients. Given the potential triggering effect of high levels of anxiety on arrhythmias, psychological support may be considered for some of the ICD patients after such public statement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2006.00468.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 36

Metadata

Authors
VAN DEN BROEK, K. C., DENOLLET, J., NYKLÍČEK, I., & VAN DER VOORT, P. H.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2006-09
Volume
29
Issue
9
Pages
953-956
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1992732437
Cited by
36
References
5
FWCI
3.72
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Psychological Reaction to Potential Malfunctioning of Implantable Defibrillators. https://app.cochat.ai/papers/10.1111/j.1540-8159.2006.00468.x
The paper
VAN DEN BROEK, K. C., DENOLLET, J., NYKLÍČEK, I., & VAN DER VOORT, P. H. (2006). Psychological Reaction to Potential Malfunctioning of Implantable Defibrillators. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2006.00468.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.