CoChat

Noninvasive Classification of Ventricular Preexcitation with Unshielded Magnetocardiography and Transesophageal Atrial Pacing and Follow‐Up

BRISINDA, DONATELLA, FENICI, RICCARDO · 2007 · Pacing and Clinical Electrophysiology
Cited by 11

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Ventricular preexcitation (VPx) is usually localized noninvasively by means of electrocardiogram (ECG) algorithms, which vary in their concordance levels. Contactless magnetocardiography (MCG) has been used as an alternate 3‐dimensional (3D) method of accessory pathways (AP) localization. The sensitivity of MCG can be increased for preoperative evaluations and planning of ablation procedures by combining it with transesophageal pacing (TEP) and electrophysiological (EP) studies. This study compared the accuracy of VPx localization with MCG with ECG algorithms, and examined the increment in diagnostic accuracy achievable with TEP. Methods: Multisite mapping from the anterior chest wall was performed with a 36‐channel MCG system. TEP allowed the evaluation of anterograde conduction properties and inducibility of arrhythmias. The reproducibility of the test and follow‐up was examined in 88 patients with Wolff–Parkinson–White (WPW) syndrome. The accuracy of MCG localization was reevaluated during pacing‐induced maximal VPx in 36 patients in whom, during MCG, the degree of VPx was highest during TEP. The gold standard for validation was effective ablation of the AP. Results: The MCG classification of VPx was accurate in 94% of AP, versus 64% and 67% with ECG, during sinus rhythm and during pacing‐induced maximal VPx, respectively. In 4.5% of cases with unclear ECG localization, MCG suggested a complex septal VPx. In all patients with successful ablations, the 3D MCG localization of the AP corresponded to the ablation site. Conclusions: MCG was more accurate than ECG for the classification of VPx and provided additional information in the non‐invasive EP assessment of patients with WPW syndrome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2007.00627.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 11

Metadata

Authors
BRISINDA, D., & FENICI, R.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2007-01
Volume
30
Issue
s1
Pages
S151-5
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2140113393
Cited by
11
References
2
FWCI
1.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Classification of Ventricular Preexcitation with Unshielded Magnetocardiography and Transesophageal Atrial Pacing and Follow‐Up. https://app.cochat.ai/papers/10.1111/j.1540-8159.2007.00627.x
The paper
BRISINDA, D., & FENICI, R. (2007). Noninvasive Classification of Ventricular Preexcitation with Unshielded Magnetocardiography and Transesophageal Atrial Pacing and Follow‐Up. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2007.00627.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.