Impact of Integration of Multislice Computed Tomography Imaging into Three‐Dimensional Electroanatomic Mapping on Clinical Outcomes, Safety, and Efficacy Using Radiofrequency Ablation for Atrial Fibrillation

MARTINEK, MARTIN, NESSER, HANS‐JOACHIM, AICHINGER, JOSEF, BOEHM, GERNOT, PURERFELLNER, HELMUT · 2007 · Pacing and Clinical Electrophysiology

Abstract

Background: Circumferential radiofrequency catheter ablation (RFCA) around the orifices of the pulmonary veins (PV) is a curative catheter‐based therapy of paroxysmal, persistent, and permanent atrial fibrillation (AF). Integration of multislice computed tomography into three‐dimensional electroanatomic mapping to guide catheter ablation has been shown to be accurate and feasible. This study investigated whether the use of such sophisticated imaging technology translates into better clinical outcomes, procedural efficacy, and safety in comparison with a control group treated with conventional three‐dimensional electroanatomic mapping. Methods: A total of 100 consecutive patients (85 male, mean age 55 ± 9 years) with multi‐drug‐resistant AF underwent RFCA. In this study we used a wide area circumferential approach with confirmed PV isolation (requiring additional ablations at the ostial level) and further lines as needed. Results: Comparison of outcome data between the conventional electroanatomic mapping (Carto XP, Biosense Webster, Diamond Bar, CA, USA) and the image integration technology (Carto MERGE, Biosense Webster) resulted in a significant improvement in procedural success for the image integration group (85.1% vs 67.9%; P = 0.018). No single case of significant PV stenosis occurred in the Carto MERGE group versus three significant stenoses in the conventional group (P = 0.098). Both procedure and fluoroscopy times remained unchanged. Conclusion: Multislice computed tomography image integration into electroanatomic mapping significantly improves the success of wide area circumferential ablation with confirmed isolation of the PV and additional lines. In addition, the safety of radiofrequency ablation with regard to the occurrence of PV stenosis is increased in comparison with a control group using conventional electroanatomic mapping alone. Procedural efficacy remains unchanged.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2007.00843.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 193

Metadata

Authors
MARTINEK, M., NESSER, H., AICHINGER, J., BOEHM, G., & PURERFELLNER, H.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2007-09-25
Volume
30
Issue
10
Pages
1215-1223
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2082358462
Cited by
193
References
2
FWCI
12.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of Integration of Multislice Computed Tomography Imaging into Three‐Dimensional Electroanatomic Mapping on Clinical Outcomes, Safety, and Efficacy Using Radiofrequency Ablation for Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8159.2007.00843.x
The paper
MARTINEK, M., NESSER, H., AICHINGER, J., BOEHM, G., & PURERFELLNER, H. (2007). Impact of Integration of Multislice Computed Tomography Imaging into Three‐Dimensional Electroanatomic Mapping on Clinical Outcomes, Safety, and Efficacy Using Radiofrequency Ablation for Atrial Fibrillation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2007.00843.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.