Gender Differences in Anxiety and Concerns about the Cardioverter Defibrillator
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: Little is known about gender differences in the response to implantable cardioverter defibrillator (ICD) therapy. We compared female and male ICD patients on anxiety, depression, health‐related quality of life (HRQL), ICD concerns, and ICD acceptance. Methods: A cohort of consecutive, surviving patients (n = 535; mean age = 61.5 ± 14.4, 81.9% male) implanted with an ICD between 1989 and 2006 completed the Hospital Anxiety and Depression Scale, the Short‐Form Health Survey (SF‐36), the ICD concerns questionnaire, and the Florida Patient Acceptance Survey. Results: High levels of anxiety (52% vs 34%, P < 0.001) and ICD concerns (34% vs 16%, P = 0.001) were more prevalent in women than men, whereas no significant differences were found on depression and device acceptance (Ps > 0.05). Women were more anxious (odds ratio [OR]: 2.60 [95% confidence interval (CI): 1.46–4.64], P < 0.01) and had more ICD concerns (OR: 1.81 [95% CI: 1.09–3.00], P < 0.05) than men, adjusting for demographic and clinical characteristics. Those ICD patients experiencing shocks were also more anxious (OR: 2.02 [95% CI: 1.20–3.42], P < 0.01) and had higher levels of ICD concerns (OR: 2.70 [95% CI: 1.76–4.16], P < 0.01). In multivariable analysis of variance, significant gender differences were found for only three of the eight subscales of the SF‐36 (the physical social functioning and the mental health subscale), with women reporting poorer HRQL on all three subscales. Conclusions: Women were more prone to experience anxiety and ICD concerns compared to men regardless of whether they had experienced shocks. In clinical practice, female ICD patients should be closely monitored, and if warranted offered psychosocial intervention, as increased anxiety has been shown to precipitate arrhythmic events in defibrillator patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Herrmann, C. (1997) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(96)00216-4 · Cited by 2,885
Gater, R., Tansella, M., Korten, A., Tiemens, B. G., Mavreas, V. G., & Olatawura, M. O. (1998) · Archives of General Psychiatry · doi:10.1001/archpsyc.55.5.405 · Cited by 390
Emotional and physical precipitants of ventricular arrhythmia
Lampert, R., Joska, T., Burg, M. M., Batsford, W. P., McPherson, C. A., & Jain, D. (2002) · Circulation · doi:10.1161/01.cir.0000031733.51374.c1 · Cited by 347 · cited 1×
“39 The importance of this may be even more relevant in women than men, since both female gender and shocks were independently associated with anxiety and ICD concerns.”
BackgroundLuyster, F. S., Hughes, J. W., Waechter, D., & Josephson, R. (2006) · Psychosomatic Medicine · doi:10.1097/01.psy.0000227722.92307.35 · Cited by 61
Cited by
Dunbar, S. B., Dougherty, C. M., Sears, S. F., Carroll, D. L., Goldstein, N. E., Mark, D. B., McDaniel, G., Pressler, S. J., Schron, E., Wang, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31825d59fd · Cited by 221
KIKKENBORG BERG, S., CASPAR THYGESEN, L., HASTRUP SVENDSEN, J., VINGGAARD CHRISTENSEN, A., & ZWISLER, A. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12490 · Cited by 61
LANG, S., BECKER, R., WILKE, S., HARTMANN, M., HERZOG, W., & LÖWE, B. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12276 · Cited by 36
Body image concerns in patients with an implantable cardioverter defibrillator: a scoping review
Frydensberg, V. S., Skovbakke, S. J., Pedersen, S. S., & Kok, R. N. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13421 · Cited by 32
Self-citationPsychological distress in patients with an implantable cardioverter defibrillator and their partners
Rottmann, N., Skov, O., Andersen, C. M., Theuns, D. A. M. J., & Pedersen, S. S. (2018) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2018.07.010 · Cited by 28
“Anxiety disorders are generally more prevalent in women than in men [36] and female gender has also been shown to be associated with higher levels of anxiety in ICD patients [37, 38].”
BackgroundSelf-citation
Metadata
- Authors
- SPINDLER, H., JOHANSEN, J. B., ANDERSEN, K., MORTENSEN, P., & PEDERSEN, S. S.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2009-04-14
- Volume
- 32
- Issue
- 5
- Pages
- 614-621
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2100539290
- Cited by
- 65
- References
- 5
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gender Differences in Anxiety and Concerns about the Cardioverter Defibrillator. https://app.cochat.ai/papers/10.1111/j.1540-8159.2009.02334.x
- The paper
- SPINDLER, H., JOHANSEN, J. B., ANDERSEN, K., MORTENSEN, P., & PEDERSEN, S. S. (2009). Gender Differences in Anxiety and Concerns about the Cardioverter Defibrillator. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2009.02334.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.