Abstract

Introduction: Syncope and presyncope are symptoms that occur infrequently in children, are unpredictable, and represent a diagnostic challenge to the physician. Conventional diagnostic investigations are often unable to establish a diagnosis, making it difficult to determine patient risk and direct appropriate therapy. The implantable loop recorder (ILR) is a medical device that was created for prolonged monitoring of heart rate and rhythm and has been used in a limited number of pediatric studies in which the cause of the syncope is unknown. Methods: This is a retrospective review of the clinical, surgical, and follow‐up data of patients who had ILR devices implanted after conventional testing failed to identify a cause for their symptoms. Results: The diagnostic yield of the ILR device in unmasking the cause for symptoms in our patient cohort was 64%. In our study, manually activated events accounted for 71% of all documented episodes and 68% of the cases involving hemodynamically important arrhythmias or transient rhythm changes. The ILR device can be safely implanted and explanted in children without significant morbidity, in most cases. None of our patients experienced any long‐term adverse events associated with placement of the device and all were alive at last follow‐up. Conclusions: The use of the ILR device is a useful tool to help unmask arrhythmias as a cause of unexplained syncope in children. Patient selection for who should and should not have an ILR device implanted will continue to influence its diagnostic utility and generate controversy among stakeholders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2009.02486.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 46

Metadata

Authors
AL DHAHRI, K. N., POTTS, J. E., CHIU, C. C., HAMILTON, R. M., & SANATANI, S.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2009-10-19
Volume
32
Issue
11
Pages
1422-1427
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2026120531
Cited by
46
References
3
FWCI
0.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Are Implantable Loop Recorders Useful in Detecting Arrhythmias in Children with Unexplained Syncope? https://app.cochat.ai/papers/10.1111/j.1540-8159.2009.02486.x
The paper
AL DHAHRI, K. N., POTTS, J. E., CHIU, C. C., HAMILTON, R. M., & SANATANI, S. (2009). Are Implantable Loop Recorders Useful in Detecting Arrhythmias in Children with Unexplained Syncope? Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2009.02486.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.