Effect of a Psychoeducational Intervention on Depression, Anxiety, and Health Resource Use in Implantable Cardioverter Defibrillator Patients
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: Psychological responses have been reported for some patients after the insertion of an implantable cardioverter defibrillator (ICD). This study tested the effects of a psychoeducational intervention on anxiety, depressive symptoms, functional status, and health resource use during the first year after ICD implantation. Methods: ICD patients (n = 246) were randomized to usual care (UC), group (GRP), or telephone counseling (TC) intervention that included education, symptom management, and coping skill training. Participants were 58 ± 11 years, 73% men, and 23% minorities. Anxiety (State‐Trait Anxiety Inventory [STAI]), depressive symptoms (Beck Depression Inventory II [BDI‐II]), and functional status (Duke Activity Status Inventory [DASI]) were measured at baseline and after 1, 3, 6, and 12 months. Health resource use and disability days were tracked. Analyses were repeated‐measures analysis of covariance to assess Group × Time effects,χ 2for percentage with clinically significant anxiety and depression at each time point, and logistic regression. Results: All groups experienced decreased anxiety and depressive symptoms over the 12 months; GRP intervention had lower STAI (P = 0.03) than UC at 3 months. Logistic regression revealed group differences for predicted probability of having depressive symptoms at 12 months (UC = 0.31, GRP = 0.17, TC = 0.13, P = 0.03). UC had greater calls to providers at 1 and 6 months (P < 0.05) and more sick/disability days at 12 months (P = 0.01) than intervention groups. Conclusions: A psychoeducational intervention reduced anxiety and depressive symptoms early after ICD implant, lowered probability of depressive symptoms at 1 year, and decreased disability days/calls to providers. These findings support further study and clinical use of both group and telephone interventions to yield better psychological outcomes after ICD implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Emotional and physical precipitants of ventricular arrhythmia
Lampert, R., Joska, T., Burg, M. M., Batsford, W. P., McPherson, C. A., & Jain, D. (2002) · Circulation · doi:10.1161/01.cir.0000031733.51374.c1 · Cited by 347
Quality of Life with Defibrillator Therapy or Amiodarone in Heart Failure
Mark, D. B., Anstrom, K. J., Sun, J. L., Clapp-Channing, N. E., Tsiatis, A. A., Davidson-Ray, L., Lee, K. L., & Bardy, G. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706719 · Cited by 260
Luyster, F. S., Hughes, J. W., Waechter, D., & Josephson, R. (2006) · Psychosomatic Medicine · doi:10.1097/01.psy.0000227722.92307.35 · Cited by 61
Cited by
Psychological interventions for coronary heart disease.
Richards, S. H., Anderson, L., Jenkinson, C. E., Whalley, B., Rees, K., Davies, P., Bennett, P., Liu, Z., West, R., Thompson, D. R., et al. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002902.pub4 · Cited by 571
Magyar-Russell, G., Thombs, B. D., Cai, J. X., Baveja, T., Kuhl, E. A., Singh, P. P., Montenegro Braga Barroso, M., Arthurs, E., Roseman, M., Amin, N., et al. (2011) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2011.02.014 · Cited by 267
Dunbar, S. B., Dougherty, C. M., Sears, S. F., Carroll, D. L., Goldstein, N. E., Mark, D. B., McDaniel, G., Pressler, S. J., Schron, E., Wang, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31825d59fd · Cited by 221
Self-citationVAZQUEZ, L. D., CONTI, J. B., & SEARS, S. F. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02787.x · Cited by 51
LANG, S., BECKER, R., WILKE, S., HARTMANN, M., HERZOG, W., & LÖWE, B. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12276 · Cited by 36
Metadata
- Authors
- DUNBAR, S. B., LANGBERG, J. J., REILLY, C. M., VISWANATHAN, B., MCCARTY, F., CULLER, S. D., O’BRIEN, M. C., & WEINTRAUB, W. S.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2009-09-25
- Volume
- 32
- Issue
- 10
- Pages
- 1259-1271
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2035039760
- Cited by
- 102
- References
- 5
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of a Psychoeducational Intervention on Depression, Anxiety, and Health Resource Use in Implantable Cardioverter Defibrillator Patients. https://app.cochat.ai/papers/10.1111/j.1540-8159.2009.02495.x
- The paper
- DUNBAR, S. B., LANGBERG, J. J., REILLY, C. M., VISWANATHAN, B., MCCARTY, F., CULLER, S. D., O’BRIEN, M. C., & WEINTRAUB, W. S. (2009). Effect of a Psychoeducational Intervention on Depression, Anxiety, and Health Resource Use in Implantable Cardioverter Defibrillator Patients. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2009.02495.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.