Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 217

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Implantation Trends and Patient Profiles for Pacemakers and Implantable Cardioverter Defibrillators in the United States: 1993-2006: IMPLANTATION TRENDS AND PATIENT PROFILES FOR PACEMAKERS AND ICDs

KURTZ, STEVEN M., OCHOA, JORGE A., LAU, EDMUND, SHKOLNIKOV, YAKOV, PAVRI, BEHZAD B., FRISCH, DANIEL, GREENSPON, ARNOLD J.·2010·Pacing and Clinical Electrophysiology

Abstract

BACKGROUND: Prior studies of cardiac rhythm management devices (pacemakers [PM] and implantable cardioverter defibrillators [ICD]) utilization in the United States have been limited to the Medicare population. We evaluated the national trends for the implantation of PMs and ICDs including the burden of device replacement. METHODS: The Nationwide Inpatient Sample was queried to identify PM and ICD patients between 1993 and 2006 using ICD-9-CM codes, including demographics, health profile, and economic data. The Charlson Comorbidity Index (CCI) and replacement burden were calculated, and changes over time studied. RESULTS: From 1993 to 2006, 2.4 million patients received a primary PM and 0.8 million received an ICD, while there were 369,000 PM replacements and 74,000 ICD replacements. Women comprised 49% of PM and 24% of ICD patients. The mean ICD replacement burden was 8.4% (range 5-22%) and decreased significantly over time (P < 0.0001) while the replacement burden for PMs was constant (mean = 13.4%, range 11-16%). ICD patients had more comorbidities than PM patients (CCI: 0.8 vs 1.1, P < 0.0001). CONCLUSIONS: The replacement burden for PMs has remained constant, while the replacement burden for ICDs has decreased. This is likely due to the stability of the patient population receiving PMs and technology maturity. Alternatively, the indications for ICD implantation have broadened, resulting in an increased number of primary ICD implantations. The age and comorbidities are increasing in those patients receiving ICDs while the PM population is stable. These data suggest that monitoring of replacement burden is warranted, given the changing populations, their disparate clinical outcomes, and economic implications to the health care system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2009.02670.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 217

Metadata

Authors
KURTZ, S. M., OCHOA, J. A., LAU, E., SHKOLNIKOV, Y., PAVRI, B. B., FRISCH, D., & GREENSPON, A. J.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2010-01-04
Volume
33
Issue
6
Pages
705-711
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2152799761
Cited by
217
References
4
FWCI
11.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implantation Trends and Patient Profiles for Pacemakers and Implantable Cardioverter Defibrillators in the United States: 1993-2006: IMPLANTATION TRENDS AND PATIENT PROFILES FOR PACEMAKERS AND ICDs. https://app.cochat.ai/papers/10.1111/j.1540-8159.2009.02670.x
The paper
KURTZ, S. M., OCHOA, J. A., LAU, E., SHKOLNIKOV, Y., PAVRI, B. B., FRISCH, D., & GREENSPON, A. J. (2010). Implantation Trends and Patient Profiles for Pacemakers and Implantable Cardioverter Defibrillators in the United States: 1993-2006: IMPLANTATION TRENDS AND PATIENT PROFILES FOR PACEMAKERS AND ICDs. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2009.02670.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.