Implantation Trends and Patient Profiles for Pacemakers and Implantable Cardioverter Defibrillators in the United States: 1993-2006: IMPLANTATION TRENDS AND PATIENT PROFILES FOR PACEMAKERS AND ICDs
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Prior studies of cardiac rhythm management devices (pacemakers [PM] and implantable cardioverter defibrillators [ICD]) utilization in the United States have been limited to the Medicare population. We evaluated the national trends for the implantation of PMs and ICDs including the burden of device replacement. METHODS: The Nationwide Inpatient Sample was queried to identify PM and ICD patients between 1993 and 2006 using ICD-9-CM codes, including demographics, health profile, and economic data. The Charlson Comorbidity Index (CCI) and replacement burden were calculated, and changes over time studied. RESULTS: From 1993 to 2006, 2.4 million patients received a primary PM and 0.8 million received an ICD, while there were 369,000 PM replacements and 74,000 ICD replacements. Women comprised 49% of PM and 24% of ICD patients. The mean ICD replacement burden was 8.4% (range 5-22%) and decreased significantly over time (P < 0.0001) while the replacement burden for PMs was constant (mean = 13.4%, range 11-16%). ICD patients had more comorbidities than PM patients (CCI: 0.8 vs 1.1, P < 0.0001). CONCLUSIONS: The replacement burden for PMs has remained constant, while the replacement burden for ICDs has decreased. This is likely due to the stability of the patient population receiving PMs and technology maturity. Alternatively, the indications for ICD implantation have broadened, resulting in an increased number of primary ICD implantations. The age and comorbidities are increasing in those patients receiving ICDs while the PM population is stable. These data suggest that monitoring of replacement burden is warranted, given the changing populations, their disparate clinical outcomes, and economic implications to the health care system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charlson, M. E., Pompei, P., Ales, K. L., & MacKenzie, C. R. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90171-8 · Cited by 49,742
Adapting a clinical comorbidity index for use with ICD-9-CM administrative databases
DEYO, R. (1992) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(92)90133-8 · Cited by 10,452
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J.-C., Erdmann, E., Freemantle, N., Gras, D., Kappenberger, L., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,276
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
Prophylactic Defibrillator Implantation in Patients with Nonischemic Dilated Cardiomyopathy
Kadish, A., Dyer, A., Daubert, J. P., Quigg, R., Estes, N. A. M., Anderson, K. P., Calkins, H., Hoch, D., Goldberger, J., Shalaby, A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033088 · Cited by 2,080
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
(1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00024-2 · Cited by 632
Prosthetic Joint Infection Risk After Total Hip Arthroplasty in the Medicare Population
Ong, K. L., Kurtz, S. M., Lau, E., Bozic, K. J., Berry, D. J., & Parvizi, J. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2009.04.027 · Cited by 555
Self-citationGoldenberg, I., Vyas, A. K., Hall, W. J., Moss, A. J., Wang, H., He, H., Zareba, W., McNitt, S., & Andrews, M. L. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.058 · Cited by 532
Gregoratos, G., Conill, A. M., Hlatky, M. A., Fellows, C., Silka, M. J., Ritchie, J., Eagle, K., Ryan, T., & Garson, A. (1998) · Journal of the American College of Cardiology · Cited by 306
Implantable Cardioverter–Defibrillators
DiMarco, J. P. (2003) · New England Journal of Medicine · doi:10.1056/nejmra035432 · Cited by 290
Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
The Cost Effectiveness of Implantable Cardioverter-Defibrillators
Zwanziger, J., Hall, W. J., Dick, A. W., Zhao, H., Mushlin, A. I., Hahn, R. M., Wang, H., Andrews, M. L., Mooney, C., Wang, H., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.032 · Cited by 221
MOND, H. G., IRWIN, M., ECTOR, H., & PROCLEMER, A. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01164.x · Cited by 165
Omapatrilat—the story of Overture and Octave
Coats, A. J. S. (2002) · International Journal of Cardiology · doi:10.1016/s0167-5273(02)00389-3 · Cited by 107
Lamas, G. A., Knight, J. D., Sweeney, M. O., Mianulli, M. J., Jorapur, V., Khalighi, K., Cook, J. R., Silverman, R., ROSENTHAL, L. S., Clapp‐Channing, N. E., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.05.021 · Cited by 96
Moss, A. J., Fadl, Y. Y., Zaręba, W., Cannom, D. S., & Hall, W. J. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01729-5 · Cited by 90
Parkash, R., Stevenson, W. G., Epstein, L. M., & Maisel, W. H. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.04.009 · Cited by 87
Review of the Registry’s First Year, Data Collected, and Future Plans
Hammill, S. C., Stevenson, L. W., Kadish, A. H., Kremers, M. S., Heidenreich, P. A., Lindsay, B. D., Mirro, M. J., Radford, M. J., Wang, Y., Lang, C. M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.07.021 · Cited by 85
Proclemer, A., Ghidina, M., Gregori, D., Facchin, D., Rebellato, L., Fioretti, P., & Brignole, M. (2008) · EP Europace · doi:10.1093/europace/eun370 · Cited by 64
Sudden Death Prevention With Implantable Devices
PASSMAN, R. S., & Kadish, A. H. (2007) · Circulation · doi:10.1161/circulationaha.106.655704 · Cited by 56
The implantable cardioverter-defibrillator
Raj, S. R., & Sheldon, R. S. (2001) · Progress in Cardiovascular Diseases · doi:10.1053/pcad.2001.29146 · Cited by 46
Indications and recommendations for pacemaker therapy.
Gregoratos, G. (2005) · PubMed · Cited by 45
Coats, A. J. S. (2002) · International Journal of Cardiology · doi:10.1016/s0167-5273(01)00629-5 · Cited by 32
Proclemer, A., Ghidina, M., Cicuttini, G., Gregori, D., & FIORETTI, P. M. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00487.x · Cited by 26
Implantable cardioverter-defibrillators: expanding indications
Naccarelli, G. V. (2004) · Current Opinion in Cardiology · doi:10.1097/01.hco.0000129666.57492.45 · Cited by 2
Cited by
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.04.033 · Cited by 780
Self-citationTrends in Permanent Pacemaker Implantation in the United States From 1993 to 2009
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.017 · Cited by 478
Self-citationSandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
Dunbar, S. B., Dougherty, C. M., Sears, S. F., Carroll, D. L., Goldstein, N. E., Mark, D. B., McDaniel, G., Pressler, S. J., Schron, E., Wang, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31825d59fd · Cited by 221
“be alert for potential school fear; and (8) consider support for coping.”
BackgroundAuthors (EHRA Task Force Members), Deharo, J. C., Bongiorni, M. G., Rozkovec, A., Bracke, F., Defaye, P., Fernandez-Lozano, I., Golzio, P. G., Hansky, B., Kennergren, C., et al. (2012) · Europace · doi:10.1093/europace/eur338 · Cited by 210
“The population requiring extraction is getting older with more complex device systems and prior procedures and more co-morbidities.(45) For the largest published single or multicentre series, each reporting on 975 or more leads, major life threatening complications occurred in 0.”
Background
Metadata
- Authors
- KURTZ, S. M., OCHOA, J. A., LAU, E., SHKOLNIKOV, Y., PAVRI, B. B., FRISCH, D., & GREENSPON, A. J.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2010-01-04
- Volume
- 33
- Issue
- 6
- Pages
- 705-711
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2152799761
- Cited by
- 217
- References
- 28
- FWCI
- 11.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.