CoChat

Left Atrial Ablation at the Anatomic Areas of Ganglionated Plexi for Paroxysmal Atrial Fibrillation: LEFT ATRIAL ABLATION OF GANGLIONATED PLEXI

Open access
POKUSHALOV, EVGENY, ROMANOV, ALEXANDER, ARTYOMENKO, SERGEY, TUROV, ALEX, SHIROKOVA, NATALYA, KATRITSIS, DEMOSTHENES G. · 2010 · Pacing and Clinical Electrophysiology
Cited by 86

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Modification of left atrial ganglionated plexi (GP) is a promising technique for the treatment of paroxysmal atrial fibrillation (AF) but its therapeutic efficacy is not established. This study aimed at evaluating the effectiveness of anatomic GP modification by means of an implantable arrhythmia monitoring device. METHODS: In 56 patients with paroxysmal AF, radiofrequency ablation at anatomic sites, where the main clusters of GP have been identified in the left atrium, was performed. In all patients, an electrocardiogram monitor (Reveal XT, Medtronic Inc., Minneapolis, MN, USA) was implanted before (n = 7) or immediately after (n = 49) AF ablation. RESULTS: Average duration of the procedure was 142 ± 18 min and average fluoroscopy time 20 ± 7 min. In total, 53-81 applications of RF energy were delivered (mean of 18.2 ± 3.8 at each of the four areas of GP ablation). Heart rate variability was assessed in 31 patients. Standard deviation of RR intervals over the entire analyzed period, the root mean square of differences between successive RR intervals, and high frequencies decreased, while HRmin, HRmean, and LF to HF ratio increased immediately postablation; these values returned to baseline 6 months after the procedure. At end of 12-month follow-up, 40 (71%) patients were free of arrhythmia recurrence. Ten patients had AF recurrence, two patients had left atrial flutter, and four patients had episodes of flutter as well as AF recurrence. Duration of episodes of AF after ablation gradually decreased over the follow-up period. CONCLUSIONS: Regional ablation at the anatomic sites of the left atrial GP can be safely performed and enables maintenance of sinus rhythm in 71% of patients with paroxysmal AF for a 12-month period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2010.02800.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 86

Metadata

Authors
POKUSHALOV, E., ROMANOV, A., ARTYOMENKO, S., TUROV, A., SHIROKOVA, N., & KATRITSIS, D. G.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2010-06-10
Volume
33
Issue
10
Pages
1231-1238
ISSN
0147-8389 (ISSN-L)
OpenAlex
W2106201827
Cited by
86
References
1
FWCI
5.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Atrial Ablation at the Anatomic Areas of Ganglionated Plexi for Paroxysmal Atrial Fibrillation: LEFT ATRIAL ABLATION OF GANGLIONATED PLEXI. https://app.cochat.ai/papers/10.1111/j.1540-8159.2010.02800.x
The paper
POKUSHALOV, E., ROMANOV, A., ARTYOMENKO, S., TUROV, A., SHIROKOVA, N., & KATRITSIS, D. G. (2010). Left Atrial Ablation at the Anatomic Areas of Ganglionated Plexi for Paroxysmal Atrial Fibrillation: LEFT ATRIAL ABLATION OF GANGLIONATED PLEXI. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2010.02800.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.